4 set send code age, 5 reverse order – Unitec POS4000 User Manual
Page 45
P O S 4 0 0 0
Document Number:
POS4010
25
Document Title:
Remote Code POS4000 Installation and Operations Manual
[ENTER]
[MENU UP/DOWN] until "Set POS MAX WASHES" appears
[ENTER]
[3][ENTER]
to select maximum of 3 wash types to be given
Note:
The current EXT POS settings will print out with a mapping of the carwash type given
vs. the carwash type requested.
3 . 1 . 9 . 4
S e t S e n d C o d e A g e
This command is used to enable the POS1 or POS2 protocol to include the response code for
code age and wash status. In some cases when this feature is not enabled (default) the receipt
printed out at the gas pump will show that the code is valid for 1 day only. Enabling this value
may cause the system to not work properly with some point of sale manufacturers. To select this
command, scroll through the External POS sub-menu until “Set Send Code Age” appears and
then press the indicated function key.
Example to set send code age enabled:
[CMD]
to select command mode
[2-System Setup]
to select "System Setup" menu
[3]
Enter your password 3
[ENTER]
[Menu up]
Until you see: "Ext. POS MENU->"
[Menu up]
Until you see “Set Send Code Age”
[Enter]
Select
function
[ 1 ]
To enable set send code age
[ENTER]
Note:
The default setting is 0, which is normal protocol.
3 . 1 . 9 . 5 R e v e r s e
O r d e r
Note:
This feature is for use with POS 1 and 2 only.
Enabling the Reverse Order function will allow the order of carwashes configured
in the External POS device to be reversed. This function is often used when the
External POS has the prices configured in descending order (wash 1 on
EXTPOS is most expensive). Since the wash prices for an entry system that
uses cash must be in ascending order at the POS4000, this function allows the
re-mapping of the washes requested at the registers and pumps. This function
must be configured w/ POS MAX WASHES to determine how to reverse the
order.
Example:
Carwash is configured w/ 3 washes: