4.4 Status Indicators

A variety of status indicators are clearly visible on each emitter

and receiver front panel (see Figure 1-3 and Section 3.4.1,

steps #3 and #4), and Section 7.7 (cascadeable models only).
Emitter: A single bi-color Red/Green Status indicator shows

whether power is applied, and whether the emitter is in RUN

mode, optional TEST mode, or Lockout status. A 7-segment

Diagnostic Display indicates a specific error code when the

emitter is in Lockout; the display also momentarily indicates the

Scan Code setting at power-up or when changed.
Receiver: Bi-color Red/Green Zone indicators show whether a

section of the defined area is aligned and clear, or is blocked

and/or misaligned. A Yellow Reset indicator shows when the

System is in RUN mode or is waiting for a reset. There are 8

Zone indicators for all model lengths, each of which indicates

Blocked/Clear conditions for approximately 1/8 of the total light

screen.
A bi-color Red/Green Status indicator shows when the OSSD

outputs are ON (Green) or OFF (Red), or the System is in

Lockout status (flashing Red). A 3-digit 7-segment Diagnostic

Figure 4-4. Receiver status indicator operation (Trip Output configured)

* NOTE: If beam 1 is blocked, Zone indicators 2-8 will be OFF, because beam 1 provides the synchronization signal for all the beams.

Flashing if Reduced Resolution is enabled.

Display indicates the receiver’s Trip (–) or Latch (L) configuration

setting and displays a specific error code when the receiver is in

Lockout. The 7-segment display also momentarily indicates the

Scan Code setting at power-up or when changed.

Operating

Status

Required

Event

Status

Indicator

Diagnostic Display

Power-up

Apply

power

Red single-

flash

Scan code flash 3x –

alternates

Run Mode

Passes

internal

tests

Green

Dash

Test Mode

Open Test

switch

Flashing

Green

Dash

Lockout

Internal/

external

fault

Flashing

Red

Displays error code (see

Section 5.1)

then

or

then

Figure 4-3. Emitter status indicator operation

Operating

Mode

Required

Event

Reset

Indicator

Status

Indicator

Zone

Indicators*

Diagnostic Displays

OSSD

Outputs

Power-up

Apply

power

OFF

Single-

Flash Red

All Single-

Flash Red

Scan code flash 3x –

alternates

OFF

Alignment Mode –

Beam 1 Blocked

Pass

internal

tests

OFF

OFF

Zone 1 Red*

Others OFF

OFF

Alignment Mode –

Beam 1 Clear

Align

Beam 1

ON

Red

Zone 1 Green

Others Red or

Green

Total number of blocked beams

OFF

Run Mode –

Clear

Align all

beams

ON

ON or

Flashing

Green

All ON Green

OFF

OFF

ON

Run Mode –

Blocked

Beam(s)

blocked

ON

Red

Red or Green*

Total number of blocked beams

OFF

Noise Detected –

Reset Interface

Flashing

Continues

previous

reading

Continues

previous

reading

Noise Detected –

EDM Interface

Continues

previous

reading

Continues

previous

reading

Flashing

Lockout

Internal/

external

fault

OFF

Flashing

Red

All OFF

Displays error code (see Section 5.1)