Components and Specifications
2.7 Specifications
2.7.1 General Specifications
Short Circuit Protection
All inputs and outputs are protected from short circuits to +24V dc or dc common.
Electrical Safety Class
(IEC 61140: 1997)
III
Safety Rating
Type 4 per IEC 61496-1, -2; Category 4 PL e, per EN ISO 13849-1; SIL 3 per IEC 61508;
SIL CL 3 per IEC 62061
Resolution
†
and
Operating Range
†
Not including blanking
14 mm models: 0.1 m to 6 m (4" to 20')
30 mm models: 0.1 m to 18 m (4" to 60')
Range decreases with use of mirrors and/or lens shields:
Lens shields – approximately 10% less range per shield.
Glass-surface mirrors – approximately 8% less range per mirror.
See the specific mirror data sheet or the Banner Safety Catalog for further information.
Effective Aperture Angle
(EAA)
Meets Type 4 requirements per IEC 61496-2, Section 5.2.9
± 2.5° @ 3 m
Enclosure
Size: See Figure 2-2
Materials: Extruded aluminum housing with yellow polyester powder finish standard (optional black or
white or nickel-plated silver finish) and well-sealed, rugged die-cast zinc end caps, acrylic
lens cover, copolyester access cover. End caps on silver models are also nickel-plated.
ESD-safe models have static-dissipative acrylic lens cover.
Rating: IEC IP65
Operating Conditions
Temperature: 0° to +55° C (+32° to 131°F)
Max. Relative Humidity: 95% maximum relative humidity (non-condensing)
Shock and Vibration
EZ-SCREEN components have passed vibration and shock tests according to IEC 61496-1. This
includes vibration (10 cycles) of 10-55 Hz at 0.35 mm (0.014") single amplitude (0.70 mm peak-to-
peak) and shock of 10 g for 16 milliseconds (6,000 cycles).
Mounting Hardware
Emitter and receiver each are supplied with a pair of swivel end-mounting brackets. Models longer
than 900 mm also include a swivel center-mount bracket. Mounting brackets are 8-gauge cold-rolled
steel, black zinc finish.
Cables and Connections
See Section 2.3 for recommended QD cables. If other cables are used with the EZ-SCREEN, the user
must verify suitability of these cables for each application.
Certifications
IEC61496-1, -2: Type 4
ISO13849-1(EN954-1): Cat4
R
C
US
NIPF(7)
UL1998, UL61496
IEC 61496-1, -2: Type 4
EN ISO 13849-1: Cat 4 PL e