Overview, Installation and alignment, Ez-screen instruction manual – Banner EZ-SCREEN Safety Light Curtain Systems User Manual
Page 41
P/N 13348
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Overview
39
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
EZ-SCREEN
Instruction Manual
Installation and Alignment
Figure 3-21. Generic hookup – FSDs (2-channel EDM, manual reset)
+24V dc
0V dc
Receiver
8-pin male
Euro-style
face view
†
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
+24V dc
Ground
0V dc
OSSD1
OSSD2
Reset*
EDM1
EDM2
FSD
2
FSD
1
Single-Channel
Safety Stop
Circuit
Dual-Channel
Safety Stop
Circuit
NOTE: Do not exceed OSSD maximum load
capacitance specification.
*Trip (auto reset) – Not connected
†
See Table 2.2 for further
QDE-8..D cable information.
Figure 3-22. Generic hookup – self-checking Safety Module, Safety Controller, Safety PLC (no monitoring, automatic reset)
+24V dc
0V dc
Receiver
8-pin male
Euro-style
face view
†
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
Jumper
+24V dc
Ground
0V dc
OSSD1
OSSD2
Reset*
EDM1
EDM2
*Trip (auto reset) – Not connected
†
See Table 2.2 for further
QDE-8..D cable information.
S1
A1 A1 A2 A2
S2
S3
SC22-3
Safety Controller
NOTE: EZ-SCREEN receiver DIP switches are configured
for “Trip” (T) output and 2-channel EDM (E2). If
the Auxiliary output is to be used, configure the
EZ-SCREEN receiver for 1-channel EDM (E1) and
connect pin #3 (Or) to +24V dc.