Shaded distances are restricted by cable capacitance charging current.
10
1000
2
24.4
(80)
45.7
(150)
61.0
(200)
91.4
(300)
182.9
(600)
243.8
(800)
2 x
1321-3R600-C
20
840
(4)
4
24.4
(80)
45.7
(150)
61.0
(200)
76.2
(250)
152.4
(500)
182.9
(600)
20
1680
1400
2
24.4
(80)
45.7
(150)
61.0
(200)
91.4
(300)
182.9
(600)
243.8
(800)
2 x
1321-3R750-C
20
840
4
24.4
(80)
45.7
(150)
61.0
(200)
76.2
(250)
152.4
(500)
182.9
(600)
20
1680
(1) Some Frame 9 and all Frame 10 drives require two reactors to match drive amp rating. The resistor ratings are per phase values for each reactor.
(2) Resistor specification is based on two parallel cables per phase.
(3) Resistor specification is based on three parallel cables per phase.
(4) Resistor specification is based on four parallel cables per phase.
Table 53 - PowerFlex 755 Floor Mount Drives, 690V Shielded/Unshielded Cable – Meters (Feet) (continued)
Drive
Rating
No Solution
Reactor Only
Reactor and
Damping Resistor
Reactor
Resistor
Available Options
Frame
kW
kHz
1488V
1850V
1488V 1850V
1488V
1850V
Cat. No.
Ohms
Watts
TFA1
TFB2
RWR2 RWC
Table 54 - 1336 PLUS II/IMPACT Drives, 380…480V – Meters (Feet)
Drive
Frame
Drive kW
(Hp)
Motor kW
(Hp)
No External Devices
(1)
with 1204-TFB2 Term.
with 1204-TFA1 Terminator
(1)(4)
Motor Motor
Motor
Motor
A
B
1329
1329R/L (1600V) A or B
1329
A
B
1329
A
B or 1329
Any
Cable
Any
Cable
Any
Cable
Any
Cabl
e
(2)
Shld
(3)
Unshld Any
Cable
Shld
Unshld
Shld
Unshld Any
Cable
Any
Cable
Any
Cable
A1
0.37 (0.5)
0.37 (0.5)
12.2
(40)
33.5
(110)
91.4
(300)
91.4
(300)
Use 1204-TFA1
30.5
(100)
61.0
(200)
30.5
(100)
61.0
(200)
91.4
(300)
22.9
(75)
182.9 (600)
0.75 (1)
0.75 (1)
12.2
(40)
33.5
(110)
91.4
(300)
91.4
(300)
30.5
(100)
30.5
(100)
30.5
(100)
30.5
(100)
91.4
(300)
22.9
(75)
182.9 (600)
0.37 (0.5)
12.2
(40)
33.5
(110)
91.4
(300)
91.4
(300)
30.5
(100)
61.0
(200)
30.5
(100)
61.0
(200)
91.4
(300)
22.9
(75)
182.9 (600)
1.2 (1.5)
1.2 (1.5)
12.2
(40)
33.5
(110)
91.4
(300)
91.4
(300)
30.5
(100)
30.5
(100)
61.0
(200)
61.0
(200)
91.4
(300)
22.9
(75)
182.9 (600)
0.75 (1)
12.2
(40)
33.5
(110)
91.4
(300)
91.4
(300)
30.5
(100)
30.5
(100)
61.0
(200)
61.0
(200)
91.4
(300)
22.9
(75)
182.9 (600)
0.37 (0.5)
12.2
(40)
33.5
(110)
114.3
(375)
121.9
(400)
30.5
(100)
30.5
(100)
61.0
(200)
61.0
(200)
121.9
(400)
22.9
(75)
182.9 (600)
- 1336E Wiring and Grounding Guide, (PWM) AC Drives 1336F Wiring and Grounding Guide, (PWM) AC Drives 1336S Wiring and Grounding Guide, (PWM) AC Drives 1336VT Wiring and Grounding Guide, (PWM) AC Drives 1336 Wiring and Grounding Guide, (PWM) AC Drives 1305 Wiring and Grounding Guide, (PWM) AC Drives 25B Wiring and Grounding Guide, (PWM) AC Drives 20N Wiring and Grounding Guide, (PWM) AC Drives 20M Wiring and Grounding Guide, (PWM) AC Drives 22C Wiring and Grounding Guide, (PWM) AC Drives 22B Wiring and Grounding Guide, (PWM) AC Drives 22A Wiring and Grounding Guide, (PWM) AC Drives 20D Wiring and Grounding Guide, (PWM) AC Drives 20C Wiring and Grounding Guide, (PWM) AC Drives 20B Wiring and Grounding Guide, (PWM) AC Drives 20A Wiring and Grounding Guide, (PWM) AC Drives 1336R Wiring and Grounding Guide, (PWM) AC Drives