Motor Cable Length Restrictions Tables Appendix A
Table 44 - PowerFlex 700S Drives, 600V Shielded/Unshielded Cable – Meters (Feet)
Drive
No Solution
Reactor Only
Reactor and Damping
Resistor or 1321-RWR
Reactor/RWR
Resistor
Available Options
Frame Hp
kHz 1488V
1850V
1488V
1850V
1488V
1850V
Cat. No.
Ohms
Watts
TF
A1
TF
B
2
RW
R2
RW
C
1
1
2/4
24.4 (80)
121.9 (400)
24.4 (80)
182.9 (600)
182.9 (600)
182.9 (600)
●
●
●
2
2/4
24.4 (80)
121.9 (400)
24.4 (80)
182.9 (600)
182.9 (600)
182.9 (600)
●
●
●
●
3
2/4
24.4 (80)
121.9 (400)
24.4 (80)
182.9 (600)
182.9 (600)
182.9 (600)
●
●
●
●
5
2/4
24.4 (80)
121.9 (400)
24.4 (80)
243.8 (800)
365.8 (1200)
365.8 (1200)
1321-RWR8-EP
●
●
●
●
7.5
2/4
24.4 (80)
121.9 (400)
24.4 (80)
304.8 (1000)
365.8 (1200)
365.8 (1200)
1321-RWR8-EP
●
●
10
2/4
24.4 (80)
121.9 (400)
24.4 (80)
365.8 (1200)
365.8 (1200)
365.8 (1200)
1321-RWR12-EP
●
●
15
2/4
24.4 (80)
121.9 (400)
36.6 (120)
365.8 (1200)
365.8 (1200)
365.8 (1200)
1321-RWR18-EP
●
2
20
2/4
24.4 (80)
121.9 (400)
36.6 (120)
365.8 (1200)
365.8 (1200)
365.8 (1200)
1321-RWR25-EP
●
25
2/4
24.4 (80)
121.9 (400)
45.7 (150)
365.8 (1200)
365.8 (1200)
365.8 (1200)
1321-RWR25-EP
●
3
30
2/4
24.4 (80)
121.9 (400)
45.7 (150)
365.8 (1200)
365.8 (1200)
365.8 (1200)
1321-RWR35-EP
●
40
2/4
24.4 (80)
137.2 (450)
45.7 (150)
365.8 (1200)
304.8 (1000)
365.8 (1200)
1321-RWR45-EP
●
50
2/4
24.4 (80)
137.2 (450)
45.7 (150)
304.8 (1000)
304.8 (1000)
365.8 (1200)
1321-RWR55-EP
●
4
60
2/4
24.4 (80)
137.2 (450)
45.7 (150)
304.8 (1000)
304.8 (1000)
365.8 (1200)
1321-RWR80-EP
●
5
75
2/4
24.4 (80)
137.2 (450)
45.7 (150)
274.3 (900)
243.8 (800)
365.8 (1200)
1321-RWR80-EP
●
100
2/4
24.4 (80)
137.2 (450)
45.7 (150)
243.8 (800)
243.8 (800)
365.8 (1200)
1321-RWR100-EP
●
6
125
2/4
24.4 (80)
137.2 (450)
61.0 (200)
243.8 (800)
198.1 (650)
365.8 (1200)
1321-RWR130-EP
●
150
2/4
24.4 (80)
137.2 (450)
61.0 (200)
243.8 (800)
198.1 (650)
365.8 (1200)
1321-RWR160-EP
●
9
150
2
24.4 (80)
137.2 (450)
61.0 (200)
243.8 (800)
198.1 (650)
365.8 (1200)
1321-RWR200-EP
●
200
2
24.4 (80)
137.2 (450)
61.0 (200)
243.8 (800)
198.1 (650)
365.8 (1200)
1321-RWR250-EP
●
10
250
2
24.4 (80)
137.2 (450)
61.0 (200)
198.1 (650)
167.6 (550)
365.8 (1200)
1321-3RB250-B
50
315
●
350
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
167.6 (550)
365.8 (1200)
1321-3RB350-B
20
585
(3)
(3) Resistor specification is based on two parallel cables per phase.
●
400
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
167.6 (550)
365.8 (1200)
1321-3RB400-B
20
●
450
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
167.6 (550)
365.8 (1200)
1321-3R500-B
20
●
11
500
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
167.6 (550)
365.8 (1200)
1321-3R500-B
20
●
600
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
152.4 (500)
365.8 (1200)
1321-3R600-B
20
●
12
(1)
(1) Frame 12 drives have dual inverters and require two output reactors. The resistor ratings are per phase values for each reactor.
700
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
152.4 (500)
365.8 (1200)
2 x 1321-3RB320-B
40
●
800
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
152.4 (500)
365.8 (1200)
2 x 1321-3RB400-C
40
480
(4)
(4) Resistor specification is based on three parallel cables per phase.
●
900
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
152.4 (500)
365.8 (1200)
2 x 1321-3R400-B
40
13
(2)
(2) Frame 13 drives require two output reactors to match drive amp rating. The resistor ratings are per phase values for each reactor.
1000
2
24.4 (80)
91.4 (300)
61.0 (200)
152.4 (500)
152.4 (500)
365.8 (1200)
2 x 1321-3R500-C
20
1100
2
24.4 (80)
91.4 (300)
53.3 (175)
137.2 (450)
137.2 (450)
365.8 (1200)
2 x 1321-3R500-B
20
720
(5)
(5) Resistor specification is based on four parallel cables per phase.
1300
2
24.4 (80)
91.4 (300)
53.3 (175)
137.2 (450)
137.2 (450)
365.8 (1200)
2 x 1321-3R600-B
20
- 1336E Wiring and Grounding Guide, (PWM) AC Drives 1336F Wiring and Grounding Guide, (PWM) AC Drives 1336S Wiring and Grounding Guide, (PWM) AC Drives 1336VT Wiring and Grounding Guide, (PWM) AC Drives 1336 Wiring and Grounding Guide, (PWM) AC Drives 1305 Wiring and Grounding Guide, (PWM) AC Drives 25B Wiring and Grounding Guide, (PWM) AC Drives 20N Wiring and Grounding Guide, (PWM) AC Drives 20M Wiring and Grounding Guide, (PWM) AC Drives 22C Wiring and Grounding Guide, (PWM) AC Drives 22B Wiring and Grounding Guide, (PWM) AC Drives 22A Wiring and Grounding Guide, (PWM) AC Drives 20D Wiring and Grounding Guide, (PWM) AC Drives 20C Wiring and Grounding Guide, (PWM) AC Drives 20B Wiring and Grounding Guide, (PWM) AC Drives 20A Wiring and Grounding Guide, (PWM) AC Drives 1336R Wiring and Grounding Guide, (PWM) AC Drives