Chapter 8
Defining Strings for Serial Ports and Viewports
8–23
Enter
key is picked. In this case, the
Event
will be tested for each
increment of the index (see “Using Repeat String” in this chapter), and
the index will specify the tool number of the event source.
Value Out of Range: If you try to enter a number which is not valid,
such as a gage number 35 (there are only 32 gages), the calculator pad
will flash the message –
Value Out of Range.
If this happens, pick an
appropriate number, and then pick the
Enter
key again.
Selecting Source Condition
After specifying the event source (
Master Range
,
Gage
, etc.) you next
specify the source condition. You do this by picking the source condition box
(the topmost box) on the
Event
menu.
Source condition box
The available options for source condition are dependent upon which type of
event source is currently selected:
•
With
Master Range
selected, the source condition options are:
−
Print Always
– String sent at the completion of each inspection. This
is the default setting.
−
Print on PASS
– String sent only if the master range passes.
−
Print on FAIL
– String sent only if the master range fails.
•
With a
Gage
,
Window
, or
Formula
selected, the options are:
−
Print if Enabled
– String sent at the completion of each inspection, as
long as the specified event source (tool or formula) is enabled.
−
Print on PASS
– String sent only if the event source (tool or formula)
passes the inspection.
−
Print on WARN
– String sent only if the result for the event source
(tool or formula) exceeds the respective warning range limits but does
not fail.
−
Print on FAIL
– String sent only if the result for the event source (tool
or formula) fails the inspection.