Download the program -20, Download the program – Rockwell Automation 1753-PCS-PAR Using RSLogix Guard PLUS! with GuardPLC Controllers User Manual
Page 60
Publication 1753-PM001A-EN-P - November 2005
3-20 Create a GuardPLC Project
Download the Program
1. Connect the GuardPLC controller to your PC’s Ethernet port
using a Cat. 5 Ethernet cable.
2. In the Hardware Management window, close the Signal Editor.
3. Right-click [60000] Resource.
4. Choose Online>Control Panel.
5. Enter the default Username (Administrator) with no password
and click OK.
The Control Panel opens.
If you are unable to go online, see Chapter 2 for information on
determining the IP address and SRS of the GuardPLC controller
and for information on the appropriate setting for your PC’s IP
address.
6. If the GuardPLC controller is in RUN mode, change to STOP
mode. Left-click the Stop icon on the Control Panel.
7. Answer Yes to the warning prompt.
TIP
You can use the [Ctrl]+[A] shortcut to enter the
default Username and Password.