Chapter 4

Programming

Table 6 - Parameter Linear List

(1)

Parameter No.

Description

Parameter No.

Description

Parameter No.

Description

1

Volts Phase A-B

46

Motor FLC

91

Data In B2

2

Volts Phase B-C

47

Overload Reset

92

Data In C1

3

Volts Phase C-A

48

OL Shunt Time

93

Data In C2

4

Current Phase A

49

OL Trip Enable

94

Data In D1

5

Current Phase B

50

Overload A Lvl

95

Data In D2

6

Current Phase C

51

Underload F Lvl

96

Data Out A1

7

Watt Meter

52

Underload F Dly

97

Data Out A2

8

Kilowatt Hours

53

Underload A Lvl

98

Data Out B1

9

Elapsed Time

54

Underload A Dly

99

Data Out B2

10

Meter Reset

55

Undervolt F Lvl

100

Data Out C1

11

Power Factor

56

Undervolt F Dly

101

Data Out C2

12

Mtr Therm Usage

57

Undervolt A Lvl

102

Data Out D1

13

Motor Speed

58

Undervolt A Dly

103

Data Out D1

14

SMC Option

59

Overvolt F Lvl

104

Motor ID

15

Motor Connection

(2)

60

Overvolt F Dly

105

CT Ratio

16

Line Voltage

61

Overvolt A Lvl

106

MV Ratio

17

Starting Mode

62

Overvolt A Dly

107

Aux1 Config

18

Ramp Time

63

Unbalance F Lvl

108

Aux3 Config

19

Initial Torque

64

Unbalance F Dly

109

Aux4 Config

20

Cur Limit Level

65

Unbalance A Lvl

110

Aux2 Config

21

Reserved 66

Unbalance

A

Dly

111

Language

22

Kickstart Time

67

Jam F Lvl

112

Timed Start

(2)

23

Kickstart Level

68

Jam F Dly

113

I Shutoff Level

(2)

24

Option 2 Input

69

Jam A Lvl

114

UTS Level

25

Starting Mode 2

70

Jam A Dly

115

Parameter Mgmt

26

Ramp Time 2

71

Stall Delay

116

Backspin Timer

27

Initial Torque 2

72

Gnd Flt Enable

117

V Shutoff Level

28

Cur Limit Level 2

73

Gnd Flt Level

118

OL Reset Level

29

Reserved

74

Gnd Flt Delay

119

Ambient Temp.

(2)

30

Kickstart Time 2

75

Gnd Flt Inh Time

120

Notch Position

(2)

31

Kickstart Level 2

76

Gnd Flt A Enable

121

Notch – Maximum

(2)

32

Stop Mode

77

Gnd Flt A Lvl

122

Start Delay

33

Stop Time

78

Gnd Flt A Dly

123

Bypass Delay

(2)

34

Pump Pedestal

(1)

79

PTC Enable

124

Fault 1

35

Braking Current

80

Phase Reversal

125

Fault 2

36

Braking Time

(3)

81

Starts Per Hour

126

Fault 3

37

Load Type

82

Restart Attempts

127

Fault 4

38

High Eff Brake

83

Restart Delay

128

Fault 5

39

Slow Speed Sel

84

Line Fault

129

Start Time E

40

Slow Speed Cur

85

Emergency Run

130

Start Time 2E

41

Slow Accel Cur

86

Current Loss

131

Stop Time E

42

Slow Running Cur

87

Logic Mask

132

Option 1 Input

43

Stopping Current

88

Data In A1

133

Stop Input

44

Overload Class

89

Data In A2

134

Elapsed Time 2

45

Service Factor

90

Data In B1

(1) Pump Control module only – see

Troubleshooting

section for guidance.

(2) Do not change these parameters from the default settings.
(3) Brake module only – Consult factory.