8 Technical data

91

2014-05-01

8.5

Measuring circuit monitoring

8.6

Voltage supply

RTD temperature probe in
three-wire circuit and
double thermocouples

Thermocouples

Current 4 to 20mA

Overrange

and underrange

Is detected

LED K1, K2, KD and KV are lit;

">>>>" flashes in the display for overrange, "<<<<" for underrange.

Probe and wire break

Is detected

LED K1, K2, KD and KV are lit;

">>>>" flashes in the display; relay output "Alarm" is inactive

LED K1, K2, KD and KV are lit;

">>>>" flashes in the display;

relay output "Alarm" is inactive

Probe short-circuit

Is detected

LED K1, K2, KD and KV are lit;

"<<<<" flashes in the display;

relay output "Alarm" is inactive

Is detected by difference

monitoring of the analog in-

puts

v

Chapter 7.3.6 "Limit

value difference, hyster-

esis"

LED K1, K2, KD and KV are lit;

"<<<<" flashes in the display;

relay output "Alarm" is inactive

Voltage supply

AC/DC 20 to 30 V, 48 to 63 Hz
AC 110 to 240 V, +10/-15 %, 48 to 63 Hz

Power consumption

12 VA

Power loss

12 W