Step 7. Install the LED Cable (option)
The preferred I/O connector for server backplanes is the Min SAS 4i
internal connector. This connector has eight signal pins to support
four SAS/SATA drives and six pins for the SGPIO (Serial General
Purpose Input/Output) side-band signals. The SGPIO bus is used
for efficient LED management and for sensing drive Locate status.
See SFF 8485 for the specification of the SGPIO bus. For backplane
without SGPIO supporting, Please refer to Section 2.4 LED cables
for fault/activity LED cable installation.
LED Management: The backplane may contain LEDs to indicate
drive status. Light from the LEDs could be transmitted to the out-
side of the server by using light pipes mounted on the SAS drive
tray. A small microcontroller on the backplane, connected via the
SGPIO bus to a SAS RAID controller, could control the LEDs. Activ-
ity: blinking 5 times/second and Fault: solid illuminated
Drive Locate Circuitry: The location of a drive may be detected by
sensing the voltage level of one of the pre-charge pins before and
after a drive is installed.
The following signals define the SGPIO assignments for the Min
SAS 4i internal connector (SFF-8087) in the SAS RAID controller.
The pin assignment of the sideband inputs follow SFF-8448 specifi-
cation.
PIN
Description
PIN
Description
SideBand0
SClock (Clock signal)
SideBand1
SLoad (Last clock of a bit
stream)
SideBand2
Ground
SideBand3
Ground
SideBand4
SDataOut (Serial data
output bit stream)
SideBand5
SDataIn (Serial data input bit
stream)
SideBand6
Reserved
SideBand7
Reserved
Step 8. Adding a Battery Backup Module (optional)
Please refer to Appendix B for installing the BBM in your SAS RAID
controller.