Appendix – DATOptic ARC-1680 Series User Manual
Page 154
APPENDIX
154
Note:
Do not remove BBM while system is running.
2. Disconnect the BBM cable from J2 on the SAS RAID controller.
3. Disconnect the battery pack cable from JP2 on the BBM.
4. Install a new battery pack and connect the new battery pack
to JP2.
5. Connect the BBM to J2 on the SAS controller.
6. Disable the write-back function from the McBIOS RAID man-
ager or McRAID storage manager.
Battery Functionality Test Procedure:
1. Writing amount of data into controller volume, about 5GB or
bigger.
2. Waiting for few seconds, power failed system by remove the
power cable.
3. Check the battery status, make sure the D13 is bright light,
and battery beeps every few seconds.
4. Power on system, and press Tab/F6 to login controller.
5. Check the controller event log, make sure the event shows
controller boot up with power recovered.
BBM Specifications
Mechanical
• Module Dimension (W x H x D): 37.3 x 13 x 81.6 mm
• BBM Connector: 2 x 6 box header
Environmental
• Operating Temperature
Temperature: 0
O
C to +40
O
C
• Humidity: 45-85%, non-condensing
• Storage Temperature
Temperature: -40
O
C to 60
O
C
• Humidity: 45-85%, non-condensing
Electrical
• Input Voltage
+3.6VDC
• On Board Battery Capacity
1100mAH (1*1100mAH)