Trouble-Shooting

7-9

NOTE:

Do not press any buttons alone or in combination except for pressing the
Protocol or the Set-Up/Quit button alone when turning the printer on, to
avoid initiating unexpected tests not permitted for the user.

2.

Adjust the vertical print alignment at Letter quality speed.
Examine the parallel bars. If the bars are aligned (not jagged), go to step 3. If the
bars are offset, repeatedly press the

button or the

button until the bars are

aligned.

3.

Adjust the vertical print alignment at Correspondence and Draft quality
speed.
Press the

button and the

button to switch Letter quality to Correspondence

and Draft quality.
Examine the parallel bars and adjust the vertical print alignment as described in
step 2.

Vertical Alignment

Buttons

Action

<

> Shift backward print position to Right

<

> Shift backward print position to Left

<

> Change to next print quality

<

> Change to previous print quality

< Exit / Save

> Save and exit to Normal mode

Vertical Alignment Adjustment