Allied Telesis SwitchBlade x8112 User Manual
Page 184
Chapter 8: Verifying the Hardware Operations of the Chassis
184
Figure 131. SHOW VERSION Command
2. Compare the version number displayed by the SHOW VERSION
command with the information in Table 19 on page 61 to confirm that
the version of the AlliedWare Plus Operating System on the controller
card supports all the hardware components in the chassis. If
necessary, update the management software on the controller card.
3. To display the status of the power supplies, fan module, and AT-
SBx81CFC400 Control Cards, use the SHOW SYSTEM
ENVIRONMENT command in the User Exec or Privileged Exec mode.
The Status column in the display provides the states of the modules.
Components are operating normally when they have an “Ok” status.
4. To display the status of the line cards, use the SHOW CARD
command in the Privileged Exec mode A line card has a state of
“Online” when it is operating normally. An example of the status
information is shown in Figure 132.
Figure 132. SHOW CARD Command
swplus# show version
AlliedWare Plus (TM) 5.4.2
Build name : SBx81CFC400-5.4.3.rel
Build date : Wed Jun 2 12:13:19 NZDR 2013
Build type : RELEASE
NEW-SNMP SNMP agent software
(c) 1996, 1998-2000 The Regents of the University of California.
All rights reserved;
.
.
.
Software Version
Number
awplus# show card
Slot
Card Type
State
---------------------------------------------------
1
AT-SBx81GP24
Online
2
AT-SBx81XS6
Online
3
AT-SBx81GP24
Online
4
AT-SBx81GS24a
Online
5
AT-SBx81CFC400
Online (Active)
6
AT-SBx81CFC400
Online (Standby)
7
AT-SBx81GP24
Online
8
AT-SBx81GS24a
Online
9
AT-SBx81GP24
Online
10
AT-SBx81XS6
Online
11
AT-SBx81GP24
Online
12
AT-SBx81GS24a
Online