beautypg.com

Allied Telesis SwitchBlade x8112 User Manual

Page 184

background image

Chapter 8: Verifying the Hardware Operations of the Chassis

184

Figure 131. SHOW VERSION Command

2. Compare the version number displayed by the SHOW VERSION

command with the information in Table 19 on page 61 to confirm that
the version of the AlliedWare Plus Operating System on the controller
card supports all the hardware components in the chassis. If
necessary, update the management software on the controller card.

3. To display the status of the power supplies, fan module, and AT-

SBx81CFC400 Control Cards, use the SHOW SYSTEM
ENVIRONMENT command in the User Exec or Privileged Exec mode.
The Status column in the display provides the states of the modules.
Components are operating normally when they have an “Ok” status.

4. To display the status of the line cards, use the SHOW CARD

command in the Privileged Exec mode A line card has a state of
“Online” when it is operating normally. An example of the status
information is shown in Figure 132.

Figure 132. SHOW CARD Command

swplus# show version

AlliedWare Plus (TM) 5.4.2

Build name : SBx81CFC400-5.4.3.rel
Build date : Wed Jun 2 12:13:19 NZDR 2013
Build type : RELEASE

NEW-SNMP SNMP agent software
(c) 1996, 1998-2000 The Regents of the University of California.

All rights reserved;

.
.
.

Software Version

Number

awplus# show card

Slot

Card Type

State

---------------------------------------------------
1

AT-SBx81GP24

Online

2

AT-SBx81XS6

Online

3

AT-SBx81GP24

Online

4

AT-SBx81GS24a

Online

5

AT-SBx81CFC400

Online (Active)

6

AT-SBx81CFC400

Online (Standby)

7

AT-SBx81GP24

Online

8

AT-SBx81GS24a

Online

9

AT-SBx81GP24

Online

10

AT-SBx81XS6

Online

11

AT-SBx81GP24

Online

12

AT-SBx81GS24a

Online