beautypg.com

Allied Telesis SwitchBlade x8112 User Manual

Page 161

background image

SwitchBlade x8112 Chassis Switch Installation Guide

161

Figure 114. Connecting the Positive (+) Power Wire with a Straight

Terminal

7. With a #3 Phillips-head screwdriver, connect the negative (-) power

lead wire to the negative terminal on the power supply, with the
remaining terminal screw removed in step 5. The negative terminal is
on the right. You may attach the terminals with the wires either above
or below the terminal block. Figure 115 on page 162 shows the wires
above the terminal block.

Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.