beautypg.com

Campbell Scientific CR23X Micrologger User Manual

Page 62

background image

SECTION 3. INSTRUCTION SET BASICS

3-8

TABLE 3.9-3. CR23X Output Instructions R = No. of Reps.

FINAL

INTER.

MEMORY

FLAG O

FLAG 0

INSTRUCTION

LOC.

VALUES

BYTES

OPTION

LOW

HIGH

69 WIND VECTOR

2+9R

2R

12

00,

2.7+8.3R

3.9+38.7R

3R

01,

2.7+8.3R

4.5+15.6R

4R

02,

2.4+8.8R

3.8+34.7R

2R

10,

2.1+8.2R

0.0+27.3R

3R

11,

2.1+8.2R

3.7+15.8R

4R

12,

1.6+6.4R

3.1+27.4R

70 SAMPLE

0

R

6

0.1

0.5+0.2R

71 AVERAGE

1+R

R

7

0.6+0.3R

1.4+1.7R

72 TOTALIZE

R

R

7

0.4+0.3R

0.9+0.6R

73 MAXIMUM

1R

R

8

0,

0.6+0.5R

1.6+1.4R

2R

2R, 3R

01,10,11

0.6+0.5R

1.6+2.8R

74 MINIMUM

1R

R

8

0,

0.6+0.5R

1.6+1.4R

2R

2R, 3R

01,10,11

0.6+0.5R

1.6+2.8R

75 HISTOGRAM

1+bins

R

BINS*R

24

0.7+1.7R

0.8+(2.8+0.7*BIN)R

77 REAL TIME

0

1 TO 4

4

0.1

2.2

78 RESOLUTION

0

0

3

0.4

0.4

79 SMPL ON MM

R

R

7

0.2

0.7+0.3R

80 STORE AREA

1

0

0

7

0.2

0.2

81 RAINFLOW HIST see

instruction

42

82 STD. DEV.

1+3R

R

7

0.8+1.0R

3.3+7.0R

TABLE 3.9-4. Program Control Instruction Memory and Execution Times

MEMORY

INTER.

PROG.

INSTRUCTION

LOC.

BYTES

EXECUTION TIME (ms)

83 IF CASE

0

10

0.23

85 LABEL SUBR.

0

3

0.08

86 DO

0

6

0.17

87 LOOP

1

10

0.16

88 IF X<=>Y

0

11

0.42

89 IF X<=>F

0

13

0.32

90 LOOP INDEX

0

3

0.40

91 IF FLAG/PORT

0

7

0.22

92 IF TIME

1

12

0.21

93 BEGIN CASE

1

8

0.16

94 ELSE

0

4

0.16

95 END

0

4

0.22

96 SERIAL OUT

0

3

97 INIT.TELE.

7

17

98 SEND CHAR.

0

3

120 GOES SAT

0 or 2

5

121 ARGOS SAT

0

8