SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES

8-13

03:

AM25TMultiplexer (P134)
1:

4

Reps

2:

11

10 mV, Fast Range

3:

1

Channel

4:

4

DIFF Channel

5:

21

Exchan 1, 60 Hz Reject

6:

1

Clock Control

7:

2

Reset Control

8:

2

Type E (Chromel-Constantan)

9:

16

Ref Temp (Deg. C) Loc [ Ref_Temp ]

10:

7

Loc [ Ta2_1 ]

11:

1.0

Mult

12:

0.0

Offset

04:

Z=X*F (P37)
1:

1

X Loc [ W1 ]

2:

1.2222

F

3:

1

Z Loc [ W1 ]

05:

Z=X*F (P37)
1:

4

X Loc [ W2 ]

2:

1.2222

F

3:

4

Z Loc [ W2 ]

06:

Block Move (P54)
1:

5

No. of Values

2:

4

First Source Loc [ W2 ]

3:

1

Source Step

4:

11

First Destination Loc
[ W2_i ]

5:

1

Destination Step

07:

Z=X (P31)
1:

9

X Loc [ Ta1 ]

2:

4

Z Loc [ W2 ]

08:

Wet/Dry Bulb Temp to VP (P57)
1:

17

Pressure Loc [ Pressure ]

2:

9

Dry Bulb Loc [ Ta1 ]

3:

10

Wet Bulb Loc [ Tw1 ]

4:

5

Loc [ U2 ]

09:

Wet/Dry Bulb Temp to VP (P57)
1:

17

Pressure Loc [ Pressure ]

2:

14

Dry Bulb Loc [ Ta2_i ]

3:

15

Wet Bulb Loc [ Tw2_i ]

4:

15

Loc [ Tw2_i ]

10:

If time is (P92)
1:

0

Minutes (Seconds --) into a

2:

30

Interval (same units as above)

3:

10

Set Output Flag High