beautypg.com

Campbell Scientific CR23X Micrologger User Manual

Page 261

background image

APPENDIX B. CONTROL PORT SERIAL I/O INSTRUCTION 15

B-17

12:

0.0

Offset

; CONFIGURE AND LOAD INPUT FILTER STRINGS
; $GPGGA and $GPVTG

02:

Extended Parameters (P63)
1:

36

Option

;$

2:

71

Option

;G

3:

80

Option

;P

4:

71

Option

;G

5:

71

Option

;G

6:

65

Option

;A

7:

0

Option

;END OF STRING 1

8:

36

Option

;$

03:

Extended Parameters (P63)
1:

71

Option

;G

2:

80

Option

;P

3:

86

Option

;V

4:

84

Option

;T

5:

71

Option

;G

6:

00

Option

;END OF STRING 2

7:

00

Option

8:

00

Option

; PERFORM DATA FORMATTING

04:

If (X<=>F) (P89)
1:

27

X Loc [ RAW_TIME ]

2:

3

>=

3:

0

F

4:

30

Then Do

; ONLY PROCESS DATA IF GPS DATA IS AVAILABLE

05:

If (X<=>F) (P89)
1:

30

X Loc [ RAW_AVAIL ]

2:

1

=

3:

1

F

4:

30

Then Do

; PARSE TIME INTO (2) INPUT LOCATIONS

06:

Z=X*F (P37)
1:

27

X Loc [ RAW_TIME ]

2:

.01

F

3:

27

Z Loc [ RAW_TIME ]

07:

Z=INT(X) (P45)
1:

27

X Loc [ RAW_TIME ]

2:

1

Z Loc [ HOUR_MIN ]

08:

Z=FRAC(X) (P44)
1:

27

X Loc [ RAW_TIME ]

2:

2

Z Loc [ SECONDS ]