Campbell Scientific CR23X Micrologger User Manual
Cr23x micrologger
Table of contents
Document Outline
- Revision and Copyright Information
- Warranty and Assistance
- Table of Contents
- Selected Operating Details
- Cautionary Notes
- CR23X MICROLOGGER OVERVIEW
- SECTION 1. FUNCTIONAL MODES
- 1.1 DATALOGGER PROGRAMS - *1, *2, *3, AND *4 MODES
- 1.2 SETTING AND DISPLAYING THE CLOCK - *5 MODE
- 1.3 DISPLAYING/ALTERING INPUT MEMORY, FLAGS, AND PORTS - *6 MODE
- 1.4 COMPILING AND LOGGING DATA - *0 MODE
- 1.5 MEMORY ALLOCATION - *
- 1.6 MEMORY TESTING AND SYSTEM STATUS - *B
- 1.7 *C MODE -- SECURITY
- 1.8 *D MODE -- SAVE OR LOAD PROGRAM
- SECTION 2. INTERNAL DATA STORAGE
- SECTION 3. INSTRUCTION SET BASICS
- 3.1 PARAMETER DATA TYPES
- 3.2 REPETITIONS (Reps)
- 3.3 ENTERING NEGATIVE NUMBERS
- 3.4 INDEXING INPUT LOCATIONS AND CONTROL PORTS
- 3.5 VOLTAGE RANGE AND OVERRANGE DETECTION
- 3.6 OUTPUT PROCESSING
- 3.7 USE OF FLAGS: OUTPUT AND PROGRAM CONTROL
- 3.8 PROGRAM CONTROL LOGICAL CONSTRUCTIONS
- 3.9 INSTRUCTION MEMORY AND EXECUTION TIME
- 3.10 ERROR CODES
- SECTION 4. EXTERNAL STORAGE PERIPHERALS
- SECTION 5. TELECOMMUNICATIONS
- SECTION 6. 9-PIN SERIAL INPUT/OUTPUT
- SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES
- 7.1 SINGLE-ENDED VOLTAGE/ SWITCHED 12 V TERMINAL - CS500
- 7.2 DIFFERENTIAL VOLTAGE MEASUREMENT
- 7.3 THERMOCOUPLE TEMPERATURES USING CR23X REFERENCE
- 7.4 THERMOCOUPLE TEMPERATURES USING AN EXTERNAL REFERENCE JUNCTION
- 7.5 107 TEMPERATURE PROBE
- 7.6 ANEMOMETER WITH PHOTOCHOPPER OUTPUT
- 7.7 TIPPING BUCKET RAIN GAUGE WITH LONG LEADS
- 7.8 100 OHM PRT IN 4 WIRE HALF BRIDGE
- 7.9 100 OHM PRT IN 3 WIRE HALF BRIDGE
- 7.10 100 OHM PRT IN 4 WIRE FULL BRIDGE
- 7.11 PRESSURE TRANSDUCER - 4 WIRE FULL BRIDGE
- 7.12 LYSIMETER - 6 WIRE FULL BRIDGE
- 7.13 227 GYPSUM SOIL MOISTURE BLOCK
- 7.14 NONLINEAR THERMISTOR IN HALF BRIDGE (CAMPBELL SCIENTIFIC MODEL 101)
- 7.15 WATER LEVEL - GEOKON'S VIBRATING WIRE PRESSURE SENSOR
- 7.16 PAROSCIENTIFIC "T" SERIES PRESSURE TRANSDUCER
- 7.17 4 TO 20 MA SENSOR USING CURS100 TERMINAL INPUT MODULE
- SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
- 8.1 COMPUTATION OF RUNNING MAXIMUM
- 8.2 RAINFALL INTENSITY
- 8.3 USING CONTROL PORTS AND LOOP TO RUN AM416 MULTIPLEXER
- 8.4 SUB 1 MINUTE OUTPUT INTERVAL SYNCHED TO REAL TIME
- 8.5 SWITCH CLOSURES ON CONTROL PORTS (RAIN GAGE)
- 8.6 SDM-A04 ANALOG OUTPUT MULTIPLEXER TO STRIP CHART
- 8.7 CONVERTING 0-360 WIND DIRECTION OUTPUT TO 0-540 FOR STRIP CHART
- 8.8 USE OF 2 FINAL STORAGE AREAS - SAVING DATA PRIOR TO EVENT
- 8.9 LOGARITHMIC SAMPLING USING LOOPS
- 8.10 COVARIANCE CORRELATION PROGRAMMING EXAMPLE
- 8.11 FAST FOURIER TRANSFORM EXAMPLES
- 8.12 USING THE SWITCHED 12 V TO POWER SENSORS
- SECTION 9. INPUT/OUTPUT INSTRUCTIONS
- 1 SINGLE-ENDED VOLTS
- 2 DIFFERENTIAL VOLTS
- 3 PULSE COUNT
- 4 EXCITE, DELAY, AND MEASURE
- 5 AC HALF BRIDGE
- 6 FULL BRIDGE WITH SINGLE DIFFERENTIAL MEASUREMENT
- 7 THREE WIRE HALF BRIDGE
- 8 DIFFERENTIAL VOLTAGE WITH EXCITATION DELAY
- 9 FULL BRIDGE WITH EXCITATION COMPENSATION
- 10 BATTERY VOLTAGE
- 11 107 THERMISTOR PROBE
- 12 207 RELATIVE HUMIDITY PROBE
- 13 THERMOCOUPLE TEMPERATURE, SINGLE-ENDED MEASUREMENT
- 14 THERMOCOUPLE TEMPERATURE, DIFFERENTIAL MEASUREMENT
- 15 CONTROL PORT SERIAL I/O
- 16 TEMPERATURE FROM PLATINUM R.T.D.
- 17 PANEL TEMPERATURE
- 18 MOVE TIME TO INPUT LOCATION
- 19 WRITE SIGNATURE TO INPUT LOCATION
- 20 SET PORT
- 21 PULSE PORT WITH DURATION
- 22 DELAY WITH OPTIONAL EXCITATION
- 23 BURST MEASUREMENT
- 24 CALIBRATION
- 25 READ PORTS
- 26 TIMER
- 27 PERIOD AVERAGE (SE)
- 28 VIBRATING WIRE MEASUREMENT
- 29 INW PS9105E
- 100 SDM TDR
- 101 SDM-INT8
- 102 SDM-SW8A
- 103 SDM-AO4
- 104 SDM-CD16AC
- 105 SDI-12 RECORDER
- 106 SDI-12 SENSOR
- 107 SDM-CSAT3
- 108 SDM-UDG01
- 109 SDMX50 CHANNEL SELECT
- 110 SDM-GROUP TRIGGER
- 113 SDM-SIO4
- 114 SET TIME
- 115 SET SDM BAUD
- 117 READ DATALOGGER ID
- 118 SDM-CAN
- 130 STATUS MONITOR
- 131 EXTENDED VIBRATING WIRE MEASUREMENT
- 132 INPUT SETTLING TIME
- 133 CONTINOUS ANALOG OU
- 134 AM25T
- 189 SDM-CS7500
- SECTION 10. PROCESSING INSTRUCTIONS
- 30 Z = F *10N
- 31 Z = X
- 32 Z = Z + 1
- 33 X + Y
- 34 X + F
- 35 X - Y
- 36 X * Y
- 37 X * F
- 38 X / Y
- 39 SQUARE ROOT
- 40 LN(X)
- 41 EXP(X)
- 42 1/X
- 43 ABS(X)
- 44 FRACTIONAL VALUE OF X
- 45 INTEGER VALUE OF X
- 46 X MOD F
- 47 XY
- 48 SIN(X)
- 49 SPATIAL MAXIMUM
- 50 SPATIAL MINIMUM
- 51 SPATIAL AVERAGE
- 52 RUNNING AVERAGE
- 53 SCALING ARRAY WITH MULTIPLIER AND OFFSET
- 54 BLOCK MOVE
- 55 5TH ORDER POLYNOMIAL
- 56 SATURATION VAPOR PRESSURE
- 57 VAPOR PRESSURE FROM WET-/DRY-BULB TEMPERATURES
- 58 LOW PASS FILTER
- 59 BRIDGE TRANSFORM
- 60 FAST FOURIER TRANSFORM
- 61 INDIRECT INDEXED MOVE
- 62 COVARIANCE/CORRELATION
- 63 PARAMETER EXTENSION
- 64 PAROSCIENTIFIC "T" SERIES PROCESSING
- 65 BULK LOAD
- 66 ARCTAN
- 67 DYNAGAGE SAP-FLOW
- 68 EXTENDED PARAMETERS 4 DIGIT
- SECTION 11. OUTPUT PROCESSING INSTRUCTIONS
- SECTION 12. PROGRAM CONTROL INSTRUCTIONS
- 83 IF CASE X < F
- 85 LABEL SUBROUTINE
- 86 DO
- 87 LOOP
- 88 IF X COMPARED TO Y
- 89 IF X COMPARED TO F
- 90 STEP LOOP INDEX
- 91 IF FLAG / PORT / MODEM
- 92 IF TIME IS
- 93 BEGIN CASE STATEMENT
- 94 ELSE
- 95 END
- 96 ACTIVATE SERIAL DATA OUTPUT
- 97 INITIATE TELECOMMUNICATIONS
- 98 SEND CHARACTER
- 111 RUN PROGRAM FROM FLASH
- 114 SET TIME
- 120 TGT1 TELONICS GOES
- 121 ARGOS
- 122 INMARSAT-C
- 123 AUTOMATIC PROGRAMMING OF A TGT1
- 220 DISPLAY CHARACTERS
- SECTION 13. CR23X MEASUREMENTS
- 13.1 FAST AND SLOW MEASUREMENT SEQUENCE
- 13.2 SINGLE-ENDED AND DIFFERENTIAL VOLTAGE MEASUREMENTS
- 13.3 THE EFFECT OF SENSOR LEAD LENGTH ON THE SIGNAL SETTLING TIME
- 13.4 THERMOCOUPLE MEASUREMENTS
- 13.5 BRIDGE RESISTANCE MEASUREMENTS
- 13.6 RESISTANCE MEASUREMENTS REQUIRING AC EXCITATION
- 13.7 CALIBRATION PROCESS
- SECTION 14. INSTALLATION AND MAINTENANCE
- 14.1 PROTECTION FROM THE ENVIRONMENT
- 14.2 POWER REQUIREMENTS
- 14.3 CR23X POWER SUPPLIES
- 14.4 SOLAR PANELS
- 14.5 DIRECT BATTERY CONNECTION TO THE CR23X WIRING PANEL
- 14.6 VEHICLE POWER SUPPLY CONNECTIONS
- 14.7 CR23X Grounding
- 14.8 POWERING SENSORS AND PERIPHERALS
- 14.9 CONTROLLING POWER TO SENSORS AND PERIPHERALS
- 14.10 MAINTENANCE
- APPENDIX A. GLOSSARY
- APPENDIX B. CR23X CONTROL PORT SERIAL I/O INSTRUCTION 15
- B.1 SPECIFICATIONS
- B.2 SELECTED OPERATING DETAILS
- B.3 INSTRUCTION 15 AND PARAMETER DESCRIPTIONS
- PARAMETER 1 - REPETITIONS
- PARAMETER 2 - CONFIGURATION CODE
- PARAMETER 3 - CTS / DELAY BEFORE SEND
- PARAMETER 4 - CONTROL PORT CONFIGURATION
- PARAMETER 5 - OUTPUT START LOCATION
- PARAMETER 6 - NUMBER OF LOCATIONS TO SEND; PREAMBLE OR DATA
- PARAMETER 7 - INPUT TERMINATION CHARACTER
- PARAMETER 8 - MAXIMUM NUMBER OF CHARACTERS TO RECEIVE
- PARAMETER 9 - DELAY FOR CLEAR-TO-SEND OR SERIAL INPUT
- PARAMETER 10 - INPUT LOCATION
- PARAMETERS 11 AND 12 - MULTIPLIER AND OFFSET
- B.4 CONTROL PORT CONFIGURATIONS AND SENSOR WIRING
- B.5 RS-232 SERIAL DATA CONFIGURATION AND DATA BUFFERING
- B.6 INPUT DATA FILTERS.
- B.7 PROGRAM EXAMPLES
- B.8 SUMMARY OF BAROMETER JUMPER CONFIGURATIONS
- APPENDIX C. ADDITIONAL TELECOMMUNICATIONS INFORMATION
- APPENDIX E. ASCII TABLE
- APPENDIX F. DYNAGAGE SAP-FLOW (P67)
- APPENDIX G. CALLBACK (CR23X INITIATED TELECOMMUNICATIONS)
- APPENDIX HCALL ANOTHER DATALOGGER VIA PHONE OR RF
- APPENDIX I. TD OPERATING SYSTEM ADDENDUM FOR CR510, CR10X, AND CR23X MANUALS
- Revision and Copyright Information
- TD and PakBus Operating System Addendum for CR510, CR10X, and CR23X Manuals
- MEASUREMENT AND CONTROL MODULE OVERVIEW
- SECTION 1. FUNCTIONAL MODES
- 1.5 MEMORY ALLOCATION - ?A
- MEMORY TESTING AND SYSTEM STATUS - ?B
- 1.7 *C MODE -- SECURITY
- 1.8 *D MODE – TRANSFER PROGRAMS, GENERAL SETTING
- 1.8.1 ERASING CURRENT PROGRAM
- 1.8.2 PROGRAM TRANSFER WITH STORAGE MODULE
- 1.8.3 FULL/HALF DUPLEX
- 1.8.4 SET DATALOGGER ID
- 1.8.5 SETTING POWERUP OPTIONS
- 1.8.6 SET INITIAL BAUD
- 1.8.7 SET PROGRAM COMPILE OPTION
- 1.8.8 SET PAKBUS ADDRESS
- 1.8.9 ALLOCATE MEMORY FOR GENERAL PURPOSE FILES
- 1.8.10 VIEW ROUTING TABLE
- 1.8.11 SET PAKBUS ROUTER BEACON INTERVAL
- 1.8.12 PAKBUS NEIGHBOR FILTER
- 1.9 *9 DATA TABLES SIZES.
- SECTION 2. INTERNAL DATA STORAGE
- SECTION 3. INSTRUCTION SET BASICS
- SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
- 8.1 COMPUTATION OF RUNNING AVERAGE
- 8.2 RAINFALL INTENSITY
- 8.3 USING CONTROL PORTS AND LOOP TO RUN AM416 MULTIPLEXER
- 8.4 INTERRUPT SUBROUTINE USED TO COUNT SWITCH CLOSURES (RAIN GAGE)
- 8.5 SDM-A04 ANALOG OUTPUT MULTIPLEXER TO STRIP CHART
- 8.6 CONVERTING 0-360 WIND DIRECTION OUTPUT TO 0-540 FOR STRIP CHART
- 8.7 LOGARITHMIC SAMPLING USING LOOPS
- SECTION 9. INPUT/OUTPUT INSTRUCTIONS
- SECTION 11. OUTPUT PROCESSING INSTRUCTIONS
- SECTION 12. PROGRAM CONTROL INSTRUCTIONS
- Wireless Networks
- PakBus Get/Send Locations (P190)
- Send Final Storage Data (P191)
- Send Message (P192)
- Wireless Network Master (P193)
- Seconds Until Transmit (P194)
- Use Remote Clock Report (P195)
- Wireless Network Remote (P196)
- Force Route (P197)
- Set Setting (P198)
- Routing Table Information (P199)
- PakBus Settings (Options | PakBus Settings)
- CR23X INDEX
- Campbell Scientific Contact Information