beautypg.com

Campbell Scientific CR23X Micrologger User Manual

Page 292

background image

APPENDIX G. CALLBACK (CR23X INITIATED TELECOMMUNICATIONS)

G-10

30: Z=F (P30)

1:

0

F

2:

0

Exponent of 10

3:

8

Z Loc [ cntr_set ]

31: Z=F (P30)

1:

0

F

2:

0

Exponent of 10

3:

9

Z Loc [ CallCntr ]

32: Do (P86)

1:

28

Set Flag 8 Low

33: End (P95)

34: IF (X<=>F) (P89)

1:

8

X Loc [ cntr_set ]

2:

1

=

3:

1

F

4:

30

Then Do

35: Z=Z+1 (P32)

1:

9

Z Loc [ CallCntr ]

36: End (P95)

37: Initiate Telecommunications (P97)

1:

21

Phone Modem/1200 Baud

2:

4

Disabled when User Flag 4 is High

3:

30

Seconds Call Time Limit

4:

0

Seconds Before Fast Retry

5:

0

Fast Retries

6:

15

Minutes before Slow Retry

7:

4

Failures Loc [ ErrorLoc ]

8:

0

Data Logger ID

38: Extended Parameters (P63)

1:

1

Option

; ASCII digit, first digit in pager number

2:

8

Option

3:

0

Option

4:

1

Option

5:

7

Option

6:

5

Option

7:

0

Option

8:

9

Option

39: Extended Parameters (P63)

1:

5

Option

2:

3

Option

3:

4

Option

; Last digit in pager number

4:

44

Option

; ASCII Decimal Equivalent Comma (2 second
delay)

5:

44

Option

6:

44

Option

7:

9

Option

; ASCII digit, first digit in pager message

8:

8

Option