beautypg.com

Campbell Scientific CR23X Micrologger User Manual

Page 216

background image

SECTION 13. CR23X MEASUREMENTS

13-16

-1

-0.5

0

0.5

1

1.5

2

2.5

3

3.5

4

-10

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

Time, Minutes

TC Temperature Error, Deg.

C

-40

-30

-20

-10

0

10

20

30

40

50

60

Temperature, Deg. C

TC Temperature Error, Channel 4

TC Temperature Error, Channel 1

TC Temperature Error, Channel 7

True TC Temperature

CR23X Reference Temperature

Terminal Cover Temperature

FIGURE 13.4-2. Thermocouple Temperature Error During Rapid Temperature Change

Base w/o Battery, Terminal Cover in Place

TABLE 13.4-1. Limits of Error for Thermocouple Wire (Reference Junction at 0°C)

Limits of Error

Thermocouple

Temperature

(Whichever is greater)

Type

Range °C

Standard

Special

T

-200 to 0

± 1.0°C or 1.5%

0 to 350

± 1.0°C or 0.75%

± 0.5°C or 0.4%

J

0 to 750

± 2.2°C or 0.75%

± 1.1°C or 0.4%

E

-200 to 0

± 1.7°C or 1.0%

0 to 900

± 1.7°C or 0.5%

± 1.0°C or 0.4%

K

-200 to 0

± 2.2°C or 2.0%

0 to 1250

± 2.2°C or 0.75%

± 1.1°C or 0.4%