Vaisala Hydromet Data Collection Platform User Manual
Page 91

Chapter 3 _______________________________________________________ AWS Client Software
VAISALA_______________________________________________________________________ 89
Use the following commands in the service connection to change the
flagging:
enable <Measurement name>
disable <Measurement name>
Examples:
>\ disable RHMeasQMH102_1
>\ disable TAMeasQMH102_1
>\ disable WMS302_1
>\ enable PWD22_1
Upon successful completion of the commands, the response is as
follows:
Successfully disabled
or
Successfully enabled
Any other returned values indicate an error.
When the measurement input is disabled:
-
All output values other than status have undefined values.
-
Sensor status shows
disabled
; refer to the list of the sensor
statuses in
-
Value status shows
INVALID
and
NOT AVAILABLE
.
where
enable
=
Enables the measurement inputs or sensors
disable
=
Disables the measurement inputs or sensors
Measurement name =
Measurement name in Lizard
NOTE
For sensors that use more than one input channel, you need to enter
separate commands for each measurement. For example, you need to
control separately the TA and RH measurements of the QMH air
temperature and relative humidity sensor.