Chapter 4 ___________________________________________________________ Troubleshooting
VAISALA______________________________________________________________________ 137
Examples:
>\ disable RHMeasQMH101_1
>\ disable TAMeasQMH101_1
>\ disable WMS302_1
>\ enable PWD22_1
Upon successful completion of the commands, the response is as
follows:
Successfully disabled
or
Successfully enabled
Any other returned values indicate an error.
When the measurement input is disabled:
-
All other output values than status have undefined values.
-
Sensor status shows
disabled
; refer to the updated list of the
sensor statuses in
-
Value status shows
INVALID
and
NOT AVAILABLE
.
NOTE
For sensors that use more than one input channel, you need to enter
separate commands for each measurement. For example, you need to
control separately the TA and RH measurements of the air temperature
and relative humidity sensor.