Figure 24 – Vaisala Hydromet Data Collection Platform User Manual
Page 51

Chapter 3 _______________________________________________________ AWS Client Software
VAISALA_______________________________________________________________________ 49
3.
From the Type list, select Client socket or Server socket as the
connection type. The fields for selecting the TCP/IP connection
parameters, shown in
0905-009
Figure 24
Creating TCP/IP Socket Connection Address
Book Entry
4.
In the Name field, enter an alphanumeric string that uniquely
identifies the connection you are creating in the Address Book.
5.
If you have multiple QML loggers on the same network, and you
are going to access them over the same TCP/IP connection, you
will need a unique identifier for each logger. To uniquely identify
the logger for which you are creating an Address Book entry, enter
a unique alphanumeric string in the Station id field. However, if
you only have a single logger on the network, you can leave the
Station id entry blank.
6.
In the Command wait timeout (ms) field, enter a value in
milliseconds that specifies for how long AWS Client will wait for
the logger to respond when AWS Client sends a requests over the
TCP/IP connection. If the request, for instance, a log file
download, succeeds within the timeout, a success message is