Sensor Status List
Table 13
Sensor Status List
Value
Description
Notes
0
Sensor is working properly (OK).
1
Not measured yet.
2
Interface is not initialized.
1
1. Value is available only for sensors with a serial interface.
3
Communication timeout has occurred.
1
4
Unknown data is received.
1
5
Communication is functioning, but the sensor reports
errors. Use sensor's own service interface to find out
the cause.
1
6
Sensor communication is paused because service
connection is opened.
1
7
Message sequence numbers are overlapping in the
Autotrac satellite transceiver interface.
1
8 ... 19
Not available.
20
Excitation failure is caused by overload in the
excitation output.
2
2. Value is available only for sensors with a conventional, that is, analog or
counter/frequency, interface.
21
The input voltage is out of range or the A/D conversion
has failed due to an internal error.
2
22
Sensor is disconnected or the connection cables are
broken.
2
23
Sensor output exceeds the min/max limits defined in
the Measurements view.
2
24
Change in sensor output has exceeded the maximum
step defined in the Measurements view.
2
25
An internal configuration error has occurred.
2
26
Error in reference measurement, which is usually
caused by damaged sensor/logger or electrical
interference.
2
27
Internal voltage error occurred or the logger is
damaged.
2
28
PMT16 calibration data error.
2
29
Data is invalid for unspecified reason.
2
30
The measurement or the sensor has been manually
disabled.
99
Sensor status is not supported.