Table 39, Qml201c logger accuracy specifications – Vaisala Hydromet Data Collection Platform User Manual
Page 153
Chapter 5 ____________________________________________________________ Technical Data
VAISALA______________________________________________________________________ 151
Temperature (operating)
-50 ... +60 °C (-58 ... 140 °F);
extended -60 ... +70 °C (-76 ... 158 °F)
Temperature (storage)
-60 ... +70 °C (-76 ... 158 °F);
extended -60 ... +70 °C (-76 ... 158 °F)
Humidity
0 ... 100 %RH
Table 39
QML201C Logger Accuracy Specifications
Property
Description/Value
All data for ambient temperature range -50 ... +60 °C unless otherwise
specified
Temperature measurement
(Pt100 sensor, measurement
range
-50 ... +80 °C)
Typical uncertainty over
temperature range
-50 ... +60 °C
<
0.04 °C
Typical uncertainty over
temperature range
-60 ... +70 °C
<
0.08 °C
Maximum error over
temperature range
-40 ... +50 °C
Less than
0.10 °C
Maximum error at 0 °C
Less than
0.04 °C
Voltage measurement
uncertainty temperature
range: -50 ... +60 °C
5.0 V range
<0.06% of reading
100V
250 mV range
<0.04% of reading
50 V
250 mV range
<0.06% of reading
6 V
25 mV range
<0.06% of reading
5 V
Voltage measurement
uncertainty temperature
range: -60 ... +70 °C
5.0 V range
<0.10% of reading
150V
250 mV range
<0.08% of reading
80 V
250 mV range
<0.10% of reading
10 V
25 mV range
<0.10% of reading
10 V
Frequency measurements
0.003% + resolution up to 20 kHz
Common mode range
+7 V/-3 V
Table 38
QML201C Logger General Specifications
(Continued)
Property