Vaisala Hydromet Data Collection Platform User Manual
Page 134

User's Guide ______________________________________________________________________
132 __________________________________________________________________M210784EN-E
It is normal to have one or two warnings after the serial connection to
the QML logger has been reset; for example, if you have turned your PC
off, you can ignore these warnings.
To see active warnings, type warnings. To clear active warnings, type
warnings clear. Warnings indicate that there are some problems in the
software.
Example:
/ W> warnings
Warning: Break
occurred 9 times first in uart.cpp[84]
during thread: 00019F60 [AbsTimerT]
object pointer: 106C [component: COM0]
Warning: Frame
occurred 14 times first in uart.cpp[83]
during thread: 00019F60 [AbsTimerT]
object pointer: 106C [component: COM0]
The
Break
and
Frame
warnings mean that most likely you have turned
your PC off and on again. This causes no trouble and you can clear the
warnings.
Warning: Device reset
occurred 1 times first in c:/libs/MAWS/adcl/kernel/
idle.cpp[52]
during thread: 00001694 [Idle]
object pointer: 163C [component: Idle]
The above warning means that you have reset the QML logger. This
causes no trouble and you can clear the warning. If you have not reset
the QML logger and the warning still occurs, contact Vaisala technical
support (see section
Warning: Data missing
occurred 2 times first in h:/MAWS/software/adcl/report/
confrep.cpp[414]
during thread: 00019C0C [AbsTimerT]
object pointer: 33A94 [component: MyRep1]
If you receive the above warning, check that the parameters sname,
pslevel, and altitude are set.
To see active errors, type errors. To clear active errors, type errors
clear. Errors indicate that there is something wrong with the sensors or
configuration. Write down the error information and contact Vaisala
technical support as described in section