Vaisala Hydromet Data Collection Platform User Manual
Page 136

User's Guide ______________________________________________________________________
134 __________________________________________________________________M210784EN-E
The versions of installed communication modules can be seen from
SYSINFO output or in the startup message if, for example, you need to
find out the version of a DSI486 module.
Example startup message from the logger:
COM0: QML201C Startup - Cold Boot
Serial # : F1335009
Hardware : QML201C-003
Software : 8.00 Alpha 4 (Apr 30 2010)
Checksum : 815AED36
Boot sw version : 8.00
Program flash : 4096kB
System RAM : 2048kB
Free memory : 1626kB
Internal temp. : 24.65'C
Active errors : NO
Active warnings : NO
Piggyback - 0 : DSI486 rev: D serial no: 932365
Piggyback - 1 : DSI486 rev: A serial no: 023212
Program flash checksum (815AED36) verification...Passed
When the logger output gives communication module DSI486 version
as "D", the version of the communication module is DSI486-B. If the
Active errors
=
Existence of active errors: YES/NO
Active warnings =
Existence of active warnings: YES/NO
Piggyback - 0
=
Type and serial number of the additional module
installed in the module slot 1
Piggyback - 1
=
Type and serial number of the additional module
installed in the module slot 2
Setup file
=
Filepath of the running setup
Setup for sw
=
Minimum logger firmware version required for
running the current setup
Setup creator
=
Setup created by
Setup created
=
Setup creation time
Setup CRC
=
Setup checksum
Lizard version
=
Lizard version used to create the setup
System uptime
=
Total time that the system has been running,
calculated from the last reset