NOTE:

When viewing the software or firmware version information, pressing

displays the Versions Menu tree.

To display System Information

1.

The default display alternates between the Storage System Name display and the World Wide

Name display.
Press any push button to select the Storage System Menu Tree display.

2.

Press

until the desired Versions Menu option appears, and then press

or

to move to

sub–menu items per

Table 24

.

Shutting down the system

CAUTION:

To power off the system for more than 96 hours, use HP Command View EVA.

You can use the Shutdown System function to implement the shutdown methods listed below. These

shutdown methods are explained in

Table 25

.

Shutting down the controller (see

Shutting the controller down

).

Restarting the system (see

Restarting the System

).

Uninitializing the system (see

Uninitializing the System

).

To ensure that you do not mistakenly activate a shutdown procedure, the default state is always NO,

indicating do not implement this procedure. As a safeguard, implementing any shutdown method

requires you to complete at least two actions.

Table 25 Shutdown methods

LCD prompt

Description

Restart System?

Implementing this procedure establishes communications between the storage

system and HP Command View EVA. This procedure is used to restore

the controller to an operational state where it can communicate with HP

Command View EVA.

Power off system?

Implementing this procedure initiates the sequential removal of controller

power. This ensures no data is lost. The reasons for implementing this

procedure include replacing a drive enclosure.

Uninitialize?

Implementing this procedure will cause the loss of all data. For a detailed

discussion of this procedure, see

Uninitializing the System

.

Shutting the controller down

Use the following procedure to access the Shutdown System display and execute a shutdown procedure.

NOTE:

HP Command View EVA is the preferred method for shutting down the controller. Shut down the

controller from the OCP only if HP Command View EVA cannot communicate with the controller.
Shutting down the controller from the OCP removes power from the controller on which the procedure is

performed only. To restore power, toggle the controller’s power switch.