Table 6 Operational I/O module status indicators

Upper

Power

Lower

Descriptions

Off

On

Off

I/O Module is operational

On

Flashing, then On

On

Top port—Fibre Channel drive enclosure signal detected.

Power—Flashes for about 90 seconds after initial power application,

then remains constant.

Bottom port—Fibre Channel drive enclosure signal detected.

On

On

On

Top port—Fibre Channel drive enclosure signal detected.

Power—Present.

Bottom port—Fibre Channel drive enclosure signal detected.

Flashing

Flashing

Flashing

When the locate function is active, all three indicators flash

simultaneously. The Locate function overrides all other indicator

functions. Therefore, an error could be detected while the Locate

function is active and not be indicated until the Locate action

terminates.

Table 7 Non-operational I/O module status indicators

Upper

Power

Lower

Descriptions

On

On

Off

Top port—Fibre Channel drive enclosure signal detected.

Power—Present.

Bottom port—No Fibre Channel drive enclosure signal detected.

Check transceiver and fiber cable connections.

NOTE:

This status applies to configurations with and without FC loop

switches.

Off

On

On

Top port—No Fibre Channel drive enclosure signal detected. Check

transceiver and fiber cable connections.

Power—Present.

Bottom port—Fibre Channel drive enclosure signal detected .

Flashing

On

On

Top port—EMU detected possible transceiver problem. Check

transceiver and fiber cable connections.

Power—Present.

Bottom port—Fibre Channel drive enclosure signal detected .

On

On

Flashing

Top port—Fibre Channel drive enclosure signal detected.

Power—Present.

Bottom port—EMU detected possible transceiver problem. Check

transceiver and fiber cable connections.

NOTE:

The EMU will not flash the lower indicator on its own. It will flash

only in response to a locate command. You can flash each of the

lights independently during a locate action.

Off

Off

Off

No I/O module power.

I/O module is nonoperational.

Check power supplies. If power supplies are operational, replace

I/O module.