beautypg.com

Environmental specifications, Power specifications, 44 environmental operating specifications – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 122: The section called “environmental specifications

background image

Environmental specifications

To ensure optimum product operation, you must maintain the operational environmental specifications

listed in

Table 44

. The ambient temperature (the enclosure air intake or room temperature) is especially

critical.

Table 44 Environmental operating specifications

Ambient temperature: +10 °C to +35 °C (+50 °F to +95 °F) with an average rate of change of 1 °C/hour

maximum and a step change of 3 °C or less. Maintaining the optimum ambient temperature within the

specified range ensures that the internal operating temperatures support the drive manufacturer’s MTBF

specifications.
Relative humidity: 40% to 60% (noncondensing) with a step change of 10% or less (noncondensing).
Air quality: Not to exceed a maximum of 500,000 particles, 0.5 micron or larger, per cubic foot of air.
Heat dissipation: 12,708 BTUs per hour.

When shipping, or placing this product in short-term storage, HP recommends maintaining the

environmental conditions listed in

Table 45

.

Table 45 Environmental shipping or short-term storage specifications

Ambient temperature: –40 °C to +66 °C (–40 °F to +151 °F)
Relative humidity: 10% to 80% (noncondensing)
Altitude: 15,240 m (50,000 ft)

Power specifications

Table 46

defines the AC power specifications for the enterprise storage system PDUs, PDMs, drive

enclosure power supplies, and controller enclosure power supplies.

Table 46 Enterprise storage system AC power specifications

Nominal input voltage

Specifications

60-Hz service

202 VAC Voltage Range Power

Receptacle

Japan 180—220 VAC, 57—63 Hz, 32 A, Single Phase 3-wire, 2-pole,

IEC 309

208 VAC Voltage Range Power

Receptacle

North America 180—220 VAC, 57—63 Hz, 30 A, Single Phase 3-wire,

2-pole, NEMA L6-30

240 VAC Voltage Range Power

Receptacle

Europe208—254 VAC, 57—63 Hz, 32 A, Single Phase 3-wire, 2-pole,

IEC 309

50–Hz service

202 VAC Voltage Range Power

Receptacle

Japan180—220 VAC, 47—63 Hz, 32 A, Single Phase 3-wire, 2-pole,

IEC 309

220 VAC Voltage Range Power

Receptacle

North America190—235 VAC, 47—63 Hz, 30 A, Single Phase 3-wire,

2-pole, NEMA L6-30

230 VAC Voltage Range Power

Receptacle

North America200—244 VAC, 47—63 Hz, 30 A, Single Phase 3-wire,

2-pole, NEMA L6-30

240 VAC Voltage Range Power

Receptacle

Europe208—254 VAC, 57—63 Hz, 32 A, Single Phase 3-wire, 2-pole,

IEC 309

The power consumption of an enterprise storage system is 3,724 W.

122