beautypg.com

Power supplies, 17 power supply and blower assembly components – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 52

background image

CXO7489A

1

3

1

4

5

2

5

6

Figure 17 Power supply and blower assembly components

1. Power supply
2. Status indicator
3. AC Input connector with bail
4. Module latch (wine-colored)
5. Blower tabs (wine-colored)
6. Blower

Power supplies

The two power supplies mount in the rear of the enclosure (see

Figure 27

). The supplies are autoranging

and operate on a country-specific AC input voltage of 202 to 240 VAC ±10%, 50 to 60 Hz, ±5%, (188

to 264 VAC, 47 to 63 Hz).
The DC outputs of this power supply are:

+5.1 VDC for the EMU, I/O module,

backplane

, and disk drives

+12.1 VDC for the disk drives

+12.5 VDC for the disk drives

The output of each power supply is 499 W, with a peak output of 681 W. A single power supply can

support an enclosure with a full complement of disks.
The power supply circuitry provides protection against:

Overloads

Short circuits

Overheating

Power supply status and diagnostic information is reported to the EMU with voltage, current, and

temperature signals.
See

Regulatory Notices and Specifications

for the enclosure power specifications.

The power supply temperature sensor provides a temperature range signal to the EMU, which uses this

signal to set the

blower

speed.

The power supply internal temperature can also control the speed of the blower. The higher the power

supply temperature, the faster the speed of the blower. If the power supply temperature exceeds a preset

value, the power supply automatically shuts down.

52

Enterprise Virtual Array hardware components