Environmental Monitoring Unit (EMU)

Dual 2–Gbps FC I/O modules—A and B loops

Dual redundant 500–W power supplies and blowers

Dual redundant blowers

For ease of management, the disk drives are referred to by their physical location, the drive bay number.

Fibre Channel loop switches

The Fibre Channel loop switch acts as a central point of interconnection and establishes a fault-tolerant

physical loop topology between the controllers and the disk enclosures. FC loop switches are required in

any configuration with more than four disk enclosures. The EVA8000 uses four loop switches and the

EVA6000 uses two switches to connect the drive enclosures to the controller pair.
The FC loop switches provide the following features. For detailed information on Fibre Channel loop

switches, see

Fibre Channel loop switches

.

2.125–Gbps operating speed

Twelve ports

Half-width, 1U size

System and port status indicators

Universal power supply that operates between 100 to 250 VAC and 50 to 60 Hz

NOTE:

Each bezel covers two FC loop switches in a space of 1U.

HSV210 and HSV200 controllers

Two controllers are contained in each rack. Each controller is contained in a separate enclosure and

provides the features listed below. For detailed information, see

HSV controllers

.

High-performance microprocessor

An Operator Control Panel (OCP)

Four 2–Gbps Fibre Channel-Switched fabric host ports (two host ports in HSV200 controller)

Four 2–Gbps Fibre Channel drive enclosure device ports (two device ports in HSV200 controller)
• Arranged in redundant pairs
• Data load/performance balanced across a pair
• Support for up to 240 disks with HSV210 and 112 with HSV200

2–GB cache per controller, mirrored, with battery backup (1–GB cache in HSV200 controller)

2–GBps FC cache mirroring ports with device port backups

Dual power supplies

In addition to managing the operation of the storage system, the HSV controllers serve as the interface

between the storage system hardware and the SAN. All host I/Os and all HP Command View EVA

management commands are processed by the controllers. Up to 18 drive enclosures are supported

by one controller pair.

Racks

The rack provides the capability for mounting standard 483 mm (19 in) wide controller and drive

enclosures. For additional information, see

Racks

.

The following racks are available:

22U Rack

25U Rack

22