beautypg.com

Emu functions, 19 emu controls and displays, Figure 19 – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 54

background image

Figure 19 EMU controls and displays

1. Status indicators:

a.

EMU—This flashing green is the heartbeat for an operational EMU.

b.

Enclosure power—When both the +5 VDC and +12 VDC are correct, this green LED is on.

c.

Enclosure fault—This amber LED is normally off. The LED is lit when an enclosure error condition exists.

2. Alphanumeric display—A two-character, seven–segment alphanumeric display of the enclosure functions

and status.
3. Function select button—The primary function of this button is to select a display group function. The

indicator is on when an error condition exists.
4. Display group select button—This button is used to view display groups and control the audible alarm. The

indicator is on when the audible alarm is muted or disabled.
5. RS232 – for use by HP-authorized service representatives
6. LCD ONLY–unused
7. CAB ONLY–enclosure address bus connector

WARNING!

To reduce the risk of electrical shock, fire, or damage to the equipment, do not plug telephone or

telecommunications connectors into the “RS232 ONLY” receptacle.

EMU functions

The primary functions of the EMU include:

Using the Enclosure Services Processor (ESP) to control the Enclosure Services Interface (ESI) and

communicate with the controllers.

Assigning the Enclosure Number (En), based upon the cabinet address bus feature.

Displaying the

bay

1 loop ID.

Monitoring enclosure operation.

Detecting, reporting, recording, and displaying conditions.

Displaying EMU, enclosure, and element status.

Implementing automatic corrective actions for some conditions.

Providing enclosure status data to the controllers.

Reporting the WWN and the logical address of all disk drives.

54