Power supply conditions – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual
Page 126
0.1.en.04 CRITICAL condition—Loop a drive link rate incorrect
The drive is capable of operating at the loop link rate but is running at a different rate. For example, the
drive is operating at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating at
the Fibre Channel link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and replace the drive in the enclosure.
3.
Observe the drive status indicators to ensure the drive is operational.
4.
Observe the EMU to ensure the error is corrected.
5.
If removing and replacing the drive did not correct the problem, replace the drive.
6.
Observe the drive status indicators to ensure the drive is operational.
7.
Observe the EMU to ensure the error is corrected.
8.
If unable to correct the problem, contact your authorized service representative.
0.1.en.05 CRITICAL condition—Loop b drive link rate incorrect
The drive is capable of operating at the loop link rate but is running at a different rate. For example, the
drive is operating at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating at
the Fibre Channel link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and replace the drive in the enclosure.
3.
Observe the drive status indicators to ensure the drive is operational.
4.
Observe the EMU to ensure the error is corrected.
5.
If removing and replacing the drive did not correct the problem, replace the drive.
6.
Observe the drive status indicators to ensure the drive is operational.
7.
Observe the EMU to ensure the error is corrected.
8.
If unable to correct the problem, contact your authorized service representative.
Power supply conditions
The format of a power supply condition report is 0.2.en.ec, where:
•
0.2. is the power supply element type number
•
en. is the two-character power supply element number
•
ec is the error code
shows the location of power supply 1 and power supply 2.
126
EMU-generated condition reports