beautypg.com

HP XP P9500 Storage User Manual

Page 457

background image

Table 110 Operation Examples in a 2DC Configuration with HyperSwap and Continuous Access

Journal Z (continued)

See

Contents

Target

Maintenance or Failure

Number

“Operating procedure
during a primary

An operation example
when the primary

During a primary
storage system failure

6

storage system failure

storage system stops

(with no information
lost from memory)

(with no information

due to a failure, with

lost from memory)”
(page 476)

no information lost
from memory. After a
HyperSwap is
executed, a delta
resync is performed.

“Operating procedure
during a local storage

An operation example
when the local storage

During a local storage
system failure (with

7

system failure (with

system stops due to a

information lost from
memory)

information lost from
memory)” (page 485)

failure, with
information lost from
memory. This
procedure uses TPC-R
to stop Cnt Ac-S Z
copy pairs with the
HyperSwap attribute,
and then recovers the
failure.

“Operating procedure
during a local storage

An operation example
when the local storage

During a local storage
system failure (with no

8

system failure (with no

system stops due to a

information lost from
memory)

information lost from
memory)” (page 487)

failure, with no
information lost from
memory. This
procedure uses TPC-R
to stop Cnt Ac-S Z
copy pairs with the
HyperSwap attribute,
and then recovers the
failure.

“Operating procedure
during remote storage

An operation example
when the remote

During a remote
storage system failure

9

system failure (with

storage system stops

(with information lost
from memory)

information lost from
memory)” (page 487)

due to a failure, with
information lost from
memory. Recover from
the failure, and then
resynchronizes the Cnt
Ac-J Z copy pairs.

“Operating procedure
during a remote

An operation example
when the remote

During a remote
storage system failure

10

storage system failure

storage system stops

(with no information
lost from memory)

(with no information

due to a failure, with

lost from memory)”
(page 490)

no information lost
from memory. Recover
from the failure, and
then reconfigures the
Cnt Ac-J Z copy pairs
after first dissolving
them and canceling
their delta resync
standby statuses.

Using a 2DC configuration with HyperSwap and Continuous Access Journal Z 457