How to view consistency group and EXCTG values
shows how to view consistency group and EXCTG values for TrueCopy
Asynchronous for Mainframe and Continuous Access Journal Z.
Table 4 How to view consistency group and EXCTG values (for TrueCopy Asynchronous for
Mainframe)
ISPF panel
Script
Value to view
Panel item
to view
Panel name
REXX variable to view
CLI command
Consistency
Time
Volume Query
Information (TCA) panel
stem.CopyGroup.n.CTTime
YKQUERY
Consistency
time
stem.Pair.TC.n.CT.TIME
YKQRYDEV
CT Delta
Copy Group Pair Status
panel
stem.CopyGroup.n.CTDelta
YKQUERY
Consistency
delta
CTDelta
Copy Group Status
Summary panel
stem.CTDelta
NOTE:
The variable stem refers to the prefix of the REXX variable structure.
For details about each item, see the HP XP P9000 for Business Continuity Manager Reference
Guide.
Table 5 How to view consistency group and EXCTG values (for Continuous Access Journal Z)
ISPF panel
Script
Value to view
Panel item to
view
Panel name
REXX variable to view
CLI command
Consistency
Time
1
Volume Query
Information (CAJ)
panel
stem.CopyGroup.n.CTTime
1
YKQUERY
Consistency
time
stem.Pair.UR.n.CT.TIME
stem.Pair.UR.n.CT.SVOL_TIME
YKQRYDEV
stem.Pair.UR.n.CT.JNL_TIME
CT Delta
1
Copy Group Pair
Status panel
stem.CopyGroup.n.CTDelta
1
YKQUERY
Consistency
delta
CTDelta
1, 2
Copy Group
Status Summary
panel
stem.CTDelta
1, 2
EXCTG
Consistency
Time
EXCTG Information
panel
stem.CopyGroup.n.Exctg.Fwd.ArbCTTime
stem.CopyGroup.n.Exctg.Rev.ArbCTTime
YKQUERY
EXCTG
consistency
time
stem.Exctg2. ArbCTTime
YKQEXCTG
EXCTG CTDelta
EXCTG Information
panel
stem.Exctg2. ArbCTDelta
YKQEXCTG
EXCTG
consistency
time
1
The values to be set and displayed depend on the value of C/T TIME MODE.
2
In a 4x4 or 4x4x4 configuration, the minimum consistency delta value among all the consistency groups in a copy group
container is set and displayed. In all other configurations, the maximum consistency delta value among all the consistency
groups in a copy group container is set and displayed.
NOTE:
The variable stem refers to the prefix of the REXX variable structure.
For details about each item, see the HP XP P9000 for Business Continuity Manager Reference
Guide.
Grouping to simplify volume operations