HP XP P9500 Storage User Manual
Page 350
Table 105 Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration (continued)
See:
Description
Target
Maintenance
or failure
No.
Create a Continuous Access Journal Z copy pair between the primary site
and the remote site, and then change the configuration to a 2DC
configuration (Primary
→ Remote).
Intermediate site
storage system
maintenance
2
site
storage
system
maintenance”
(page 355)
Suspend the Continuous Access Journal Z copy pair between the intermediate
site and the remote site, and then change the configuration to a 2DC
configuration (Primary
→ Intermediate).
Remote site storage
system maintenance
3
site
storage
system
maintenance”
(page 358)
Reverse the copy direction of the Continuous Access Journal Z copy pair
between the primary site and the intermediate site, and then change the
Primary site host
maintenance
4
configuration to a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration
in which operation is performed from the intermediate site (Intermediate
→
Primary, and Intermediate
→ Remote).
--
Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.
Intermediate site host
maintenance
5
--
Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.
Remote site host
maintenance
6
Suspend the Continuous Access Journal Z copy pair between the primary
site and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate
→ Remote).
Primary site storage
system failure (with
information lost from
memory)
Failure
7
during a
primary
site
storage
system
failure
(with
information
lost from
memory)”
(page 362)
Suspend the Continuous Access Journal Z copy pair between the primary
site and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate
→ Remote).
Primary site storage
system failure (with
no information lost
from memory)
8
during a
primary
site
storage
system
failure
(with no
information
lost from
memory)”
(page 362)
Create a Continuous Access Journal Z copy pair between the primary site
and the remote site, and then change the configuration to a 2DC
Intermediate site
storage system
9
configuration (Primary
→ Remote). During recovery, the Continuous Access
failure (with
Journal Z copy pairs must be re-created between the primary site and the
intermediate site, and between the intermediate site and the remote site.
information lost from
memory)
350 Maintenance and troubleshooting operations