Link Incident Log

159

Usin

g Lo

gs

Port

The number of the port on which the incident occurred.

Link Incident

A short description of the incident. The following events may cause a link incident to
be written to the log.

– Implicit incident.

The attached node detects a condition that may cause problems on the link.

– Bit-error threshold exceeded.

The number of code violation errors has exceeded threshold.

– Loss-of-signal or loss-of-synchronization.

A loss-of-synchronization condition has persisted for longer than the resource
allocation time out value (R_A_TOV).

This occurs if a cable is unplugged from an attached node.

– Not-operational (NOS) primitive sequence received.

A NOS was recognized.

– Primitive sequence timeout.

Link reset protocol timeout occurred. A Timeout occurred for an appropriate
response while in NOS receive state and after NOS is no longer recognized.

– Invalid primitive sequence received for the current link state.

Either a link reset or a link reset response primitive sequence was recognized while
waiting for the offline sequence.

Refer to the diagnostics chapter in the hp surestore director fc-64 Installation and Service
Manual
(HP A6534-90902) for corrective actions in response to these link incident
messages.