Event Log

155

Usin

g Lo

gs

FRU Position

An acronym representing the FRU type, followed by a number representing the FRU
chassis position. FRU acronyms are:

BKPLNE - backplane.

CTP - control processor (CTP) card.

SBAR - serial crossbar (SBAR) card.

FPM - fiber port module (FPM) card.

FAN - fan module.

PWR - power supply.

The chassis (slot) position for a nonredundant FRU is 0. The chassis positions for
redundant FRUs are 0 and 1. The chassis positions for FPM cards are 0 through 15.

Event Data

Up to 32 bytes of supplementary information for the event in hexadecimal format. For
detailed information on event data and problem resolution, refer to the event code
tables appendix in the hp surestore director fc-64 Installation and Service Manual
(HP A6534-90902).