Configure Threshold Alerts

Figure 52

New Threshold Alerts Dialog Box - Second Screen

6.

Enter a percentage from 1 through 100 for % utilization. When throughput reaches this
percentage of port capacity, a threshold alert will occur.

7.

Enter the amount of cumulative minutes in which the % utilization should exist during
the notification interval before an alert is generated. You can also select At any time if
you want an alert to occur whenever the set % utilization is reached. The valid range is
1 to the interval set in step 8 (following).

8.

Enter the interval in minutes in which throughput is measured and threshold
notifications can occur. The valid range is 5 minutes to 70,560 minutes.

9.

Click Next.

A new screen appears for selecting ports for the alerts.