3-4 setting the host group, 3-5 setting the wwn information – HP StorageWorks XP Remote Web Console Software User Manual
Page 87
![background image](/manuals/397306/87/background.png)
Configuration File Loader 87
5-3-4 Setting the Host Group
The [HostGroup] tag allows you to add, delete, or change the host group information. The following parameters
apply:
•
You can delete the settings for host group 0 (zero), but the host group itself cannot be deleted. If you delete
all the settings for host group 0, the settings revert to the default settings.
•
When you delete a host group, the WWN and path definition of that host group are automatically deleted.
Therefore, if you write the settings for a host group that is deleted in the [LUN] tag or [WWN] tag, an error
occurs.
Table 5-7 lists the items and values available for the [HostGroup] tag.
Table 5-7
Available Configuration Values for the [HostGroup] Tag
Column
Item
Available Values
1st, 8th (Index)
Port
One of the following can be set:
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R,
2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R,
3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 3J, 3K, 3L, 3M, 3N, 3P, 3Q, 3R,
4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4J, 4K, 4L, 4M, 4N, 4P, 4Q, 4R
2nd, 9th (Index)
Group ID
00 – 7F. Set with hexadecimal numbers in two digits.
3rd , 10th
Group Name
Up to 8 ASCII characters (letters, numerals, and symbols). The setting is case-
sensitive.
4th, 11th
Host Mode
00 - 1F
5th, 6th, 12th, 13th Blank
5-3-5 Setting the WWN Information
The [WWN] tag allows you to add, delete, or change the WWN information. Table 5-8 lists the items and
values available for the [WWN] tag.
Table 5-8
Available Configuration Values for the [WWN] Tag
Column
Item
Available Values
1st, 8th (Index)
Port
One of the following can be set:
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R,
2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R,
3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 3J, 3K, 3L, 3M, 3N, 3P, 3Q, 3R,
4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4J, 4K, 4L, 4M, 4N, 4P, 4Q, 4R
2nd, 9th (Index)
Group ID
00 -7F. Set with hexadecimal numbers in two digits.
3rd, 10th (Index)
WWN
Set with hexadecimal numbers in 16 digits.
4th, 11th
Name
Up to 8 ASCII characters (letters, numerals, and symbols). The setting is case-
sensitive.
5th, 6th, 12th , 13th
Blank