Kit components – HP Latex 3000 Printer User Manual
Page 39

CAUTION:
Ensure that the operating temperature of the substrate recommended by the manufacturer is
not exceeded. If this information is not available, ask the manufacturer. Do not load substrates that cannot
be used at an operating temperature above 125°C (257°F).
CAUTION:
Proper maintenance and genuine HP consumables are required to ensure that the printer
operates safely as designed. The use of non-HP consumables (foams, filters, printhead cleaner roll, or inks)
may present a risk of fire.
CAUTION:
Do not load substrates with auto-ignition temperatures below 250°C (482°F). Ensure that no
ignition sources are close to the substrate.
NOTE:
Test method based on EN ISO 6942:2002: Evaluation of materials and material assemblies when
exposed to a source of radiant heat, method B. The test conditions, to determine the temperature when the
substrate starts ignition (either flame or glow) are: Heat flux density: 30 kW/m², copper calorimeter, K type
thermocouple.
The above image is a QR code containing a link to a video; see
Kit components
1.
Ink-collector container
2.
Six ink collectors with two replaceable foams
ENWW
The ink collector kit
33