Replace the drying lamps – HP Latex 3000 Printer User Manual
Page 194

Clean the perforated plate
▲
Lying on the floor as shown in the picture, clean the perforated plate of the curing modules with a lint-
free cloth dampened with isopropyl alcohol.
NOTE:
If you are in an area (such as California) that regulates VOC cleaning and maintenance fluids,
instead of isopropyl alcohol use a VOC-certified cleaner such as a properly diluted Simple Green All-
Purpose Cleaner.
Finish off cleaning the perforated plate
1.
Push the curing assembly back to its working position.
2.
Close the curing latches.
3.
Put the spindle back in position.
4.
Ensure that the cleaned parts are completely dry and all vapor has completely evaporated.
5.
Turn on the printer in the correct way for maintenance operations: see
Turn the printer on on page 143
.
Replace the drying lamps
Risk of burns
Crush hazard
Risk of trapped
fingers
Hazardous moving
part
Light radiation hazard
Electric shock hazard
For more safety information, see
Prepare to replace the drying lamps
1.
Ensure that you have the Drying Filter Lamps Kit (CZ056-67322), which is included in the Printer
Maintenance Kit (CZ056-67391) and in the Standard Uptime Kit (D4J02A).
2.
Ensure that the printer is not printing.
3.
Ensure that all windows, covers, and doors are closed and remain in their original position.
188 Chapter 8 Hardware maintenance
ENWW