Acoustic specifications – HP Latex 3000 Printer User Manual
Page 303

Table 14-8
Printer environmental specifications (continued)
Temperature range
Humidity range
Temperature gradient
Not operating, in transport or
storage, ink in tubes
5 to 55°C (41 to 131°F)
90% relative humidity at 55°C
(131°F)
10°C/h (18°F/h) or less
Not operating, in transport or
storage, no ink in tubes *
–25 to 55°C (–13 to 131°F)
90% relative humidity at 55°C
(131°F)
10°C/h (18°F/h) or less
* If the printer is going to be kept at a temperature of less than 5°C, call your service representative to empty
the ink from the tubes.
Maximum operating altitude: 3000 m (10000 ft)
The printer should not be exposed to direct sunlight or any other strong light source, and it should not be
used in a dusty environment.
Acoustic specifications
Printer acoustic specifications (declared according to ISO 9296).
Table 14-9
Printer acoustic specifications
Idle sound power level
8.8 B (A)
Operating sound power level
8.2 B (A)
Idle sound pressure at bystander position
< 60 dB (A)
Operating sound pressure at bystander position
< 67 dB (A)
< 75 db (A) during cool-down
ENWW
Acoustic specifications 297