4 controlbox and parameterbox, 5 info parameters, Controlbox and parameterbox – NORD Drivesystems BU0550 User Manual
Page 90: Info parameters
PLC logic for NORD SK 54xE frequency inverters
90
BU 0550 GB-0813
Index
Name
Function
Standardisation
Type
Access
62
_62_Inverter_32Bit_set_val1
Resulting 32Bit main setpoint 1 Bus
- Low word in P546[1]
- High word in P546[2]
_
DINT
R
63
_63_Inverter_32Bit_act_val1
FI 32Bit Actual value 1
- Low word in P543[1]
- High word in P543[2]
_
DINT
R
64
_64_Inverter_32Bit_lead_val1
32Bit master value 1
- Low word in P502[1]
- High word in P502[2]
_
DINT
R
65
_65_Broadcast_32Bit_set_val1 32Bit Broadcast Slave auxiliary set-
point 1
- Low word in P543[1]
- High word in P543[2]
_
DINT
R
66
_66_BusIO_input_bits
Incoming BusI/O data
- Bit1
– 8 = Bus I/O In Bit 0 – 7
- Bit 9 = Flag 1
- Bit 10 = Flag 2
- Bit 11 = Bit8 of the Bus control word
- Bit 12 = Bit9 of the Bus control word
_
INT
R
Table 106 Process values for bus setpoints and actual values
4.2.4
ControlBox and ParameterBox
The control boxes can be accessed via the process values listed here. This enables the implementation of
simple HMI applications.
Index
Name
Function
Standardisation
Type
Access
70
_70_Set_controlbox_show_val Display value for the
ControlBox
Display value = Bit 29
– Bit 0
Decimal point position = Bit 31 - Bit
30
DINT
R/W
71
_71_Controlbox_key_state
ControlBox keyboard status
Bit 0:
ON
Bit 1:
OFF
Bit 2:
DIR
Bit 3:
UP
Bit 4:
DOWN
Bit 5:
Enter
BYTE R
72
_72_Parameterbox_key_state
ParameterBox keyboard
status
Bit 0:
ON
Bit 1:
OFF
Bit 2:
DIR
Bit 3:
UP
Bit 4:
DOWN
Bit 5:
Enter
Bit 6:
Right
Bit 7:
Left
BYTE R
Table 107 ControlBox and ParameterBox process values
4.2.5
Info parameters
The most important actual values for the frequency inverter are listed here.
Index
Name
Function
Standardisation
Type
Access
80
_80_Current_fault
Number of actual fault
Error 10.0 = 100
BYTE
R
81
_81_Current_warning
Actual warning
Warning 10.0 = 100
BYTE
R
82
_82_Current_reason_FI_blocked
Actual reason for switch-on block
state
Problem 10.0 = 100
BYTE
R
83
_83_Input_voltage
Actual mains voltage
100 V = 100
INT
R
84
_84_Current_frequency
Actual frequency
10Hz = 100
INT
R
85
_85_Current_set_point_frequency1
Actual setpoint frequency from the
setpoint source
10Hz = 100
INT
R