PLC logic for NORD SK 54xE frequency inverters

56

BU 0550 GB-0813

3.5.2.5

MC_MoveRelative

Except for the input DISTANCE this is identical to MC_MoveAbsolute. The setpoint position results from the
addition of the present actual position and the transferred DISTANCE.

Table 75 MC_MoveRelative

3.5.2.6

MC_MoveAdditive

Except for the input DISTANCE this is identical to MC_MoveAbsolute. The setpoint position results from the
addition of the present setpoint position and the transferred DISTANCE.

Table 76 MC_MoveAdditive

VAR_INPUT

VAR_OUTPUT

Input

Explanation

Type

Output

Explanation

Type

EXECUTE

Enable

BOOL

DONE

Specified setpoint position reached

BOOL

DISTANCE

Setpoint position

DINT

BUSY

Setpoint position not reached

BOOL

VELOCITY

Setpoint frequency

INT

COMMAND-
ABORTED

Command aborted

BOOL

MODE

Mode source is the setpoint
position

BOOL

ERROR

Error in FB

BOOL

ERRORID

Error code

INT

ERRORID

Explanation

0

No error

1000h

FI is not enabled

1200h

Position control not activated

1201h

The High position has not been entered in the PLC setpoints (P553)

1202h

The Low position has not been entered in the PLC setpoints (P553)

VAR_INPUT

VAR_OUTPUT

Input

Explanation

Type

Output

Explanation

Type

EXECUTE

Enable

BOOL

DONE

Specified setpoint position reached

BOOL

DISTANCE

Setpoint position

DINT

BUSY

Setpoint position not reached

BOOL

VELOCITY

Setpoint frequency

INT

COMMAND-
ABORTED

Command aborted

BOOL

MODE

Mode source is the setpoint
position

BOOL

ERROR

Error in FB

BOOL

ERRORID

Error code

INT

ERRORID

Explanation

0

No error

1000h

FI is not enabled

1200h

Position control not activated

1201h

The High position has not been entered in the PLC setpoints (P553)

1202h

The Low position has not been entered in the PLC setpoints (P553)