4 Frequency inverter details
BU 0550 GB-0813
89
Index Name
Function
Standardisation
Type
Access
34
_34_PLC_Busmaster_Control_word
Master function con-
trol word (bus master
function) via PLC
Corresponds to USS profile
INT
R/W
35
_35_PLC_32Bit_set_val1
32Bit PLC setpoint
- P553[1] = Low
word
of
the 32Bit value
- P553[2] = High
word
of the 32Bit value
_
DINT
R/W
36
_36_PLC_32Bit_act_val1
32Bit PLC actual val-
ue
- PLC actual value 1 =
Low
word
of the 32Bit
value
- PLC actual value 2 =
High
word
of the 32Bit
value
_
DINT
R/W
Table 105 Process values for PLC setpoints and actual values
4.2.3
Bus setpoints and actual values
These process values reflect all setpoints and actual values which are transferred to the frequency inverter
via the various bus systems.
Index Name
Function
Standardisation
Type
Access
40
_40_Inverter_status
FI Status word
Corresponds to
USS profile
INT
R
41
_41_Inverter_act_val1
FI Actual value 1
100% = 4000h
INT
R
42
_42_Inverter_act_val2
FI Actual value 2
100% = 4000h
INT
R
43
_43_Inverter_act_val3
FI Actual value 3
100% = 4000h
INT
R
44
_44_Inverter_act_val4
FI Actual value 4
100% = 4000h
INT
R
45
_45_Inverter_act_val5
FI Actual value 5
100% = 4000h
INT
R
46
_46_Inverter_lead_val1
Broadcast Master Function: Master
value 1
100% = 4000h
INT
R
47
_47_Inverter_lead_val2
Broadcast Master Function: Master
value 2
100% = 4000h
INT
R
48
_48_Inverter_lead_val3
Broadcast Master Function: Master
value 3
100% = 4000h
INT
R
49
_49_Inverter_lead_val4
Broadcast Master Function: Master
value 4
100% = 4000h
INT
R
50
_50_Inverter_lead_val5
Broadcast Master Function: Master
value 5
100% = 4000h
INT
R
51
_51_Inverter_control_word
Resulting bus control word
Corresponds to
USS profile
INT
R
52
_52_Inverter_set_val1
Resulting main bus setpoint 1
100% = 4000h
INT
R
53
_53_Inverter_set_val2
Resulting main bus setpoint 2
100% = 4000h
INT
R
54
_54_Inverter_set_val3
Resulting main bus setpoint 3
100% = 4000h
INT
R
55
_55_Inverter_set_val4
Resulting main bus setpoint 4
100% = 4000h
INT
R
56
_56_Inverter_set_val5
Resulting main bus setpoint 5
100% = 4000h
INT
R
57
_57_Broadcast_set_val1
Broadcast Slave: Auxiliary setpoint 1
100% = 4000h
INT
R
58
_58_Broadcast_set_val2
Broadcast Slave: Auxiliary setpoint 2
100% = 4000h
INT
R
59
_59_Broadcast_set_val3
Broadcast Slave: Auxiliary setpoint 3
100% = 4000h
INT
R
60
_60_Broadcast_set_val4
Broadcast Slave: Auxiliary setpoint 4
100% = 4000h
INT
R
61
_61_Broadcast_set_val5
Broadcast Slave: Auxiliary setpoint 5
100% = 4000h
INT