beautypg.com

2 plc setpoints and actual values – NORD Drivesystems BU0550 User Manual

Page 88

background image

PLC logic for NORD SK 54xE frequency inverters

88

BU 0550 GB-0813

Index

Name

Function

Standardisation

Type

Access

6

_6_Delay_digital_inputs

State of digital inputs according
to P474

Bit 0: DIN1

Bit 1: DIN2

Bit 2: DIN3

Bit 3: DIN4

Bit 4: DIN5

Bit 5: DIN6

Bit 6: DIN7

Bit 7: Digital function AIN1

Bit 8: Digital function AIN2

INT

R

7

_7_Analog_input1

Value of analog input 1 (AIN1)

10.00V = 1000

INT

R

8

_8_Analog_input2

Value of analog input 2 (AIN2)

10.00V = 1000

INT

R

9

_9_Analog_input3

Value of analog function DIN2

10.00V = 1000

INT

R

10

_10_Analog_input4

Value of analog function DIN3

10.00V = 1000

INT

R

11

_11_External_analog_input1

Value of analog input 1 (1.IOE)

10.00V = 1000

INT

R

12

_12_External_analog_input2

Value of analog input 2 (1.IOE)

10.00V = 1000

INT

R

13

_13_External_analog_input3

Value of analog input 1 (2.IOE)

10.00V = 1000

INT

R

14

_14_External_analog_input4

Value of analog input 2 (2.IOE)

10.00V = 1000

INT

R

15

_15_State_analog_output

Status of analog output

10.0V = 100

BYTE

R

16

_16_State_ext_analog_out1

Status of analog output (1 IOE)

10.00V = 1000

INT

R

17

_17_State_ext_analog_out2

Status of analog output 2 (2 IOE)

10.00V = 1000

INT

R

Table 104 Input and output process values

4.2.2

PLC setpoints and actual values

The process values listed here form the interface between the PLC and the frequency inverter. The function
of the PLC setpoints is specified in (P553).

NOTE

The process value _20_PLC_control_word overwrites the function block MC_Power. The PLC
setpoints overwrite the function blocks MC_Move…. and MC_Home.

Index

Name

Function

Standardisation

Type

Access

20

_20_PLC_control_word

PLC control word

Corresponds to USS profi-
le

INT

R/W

21

_21_PLC_set_val1

PLC setpoint 1

100% = 4000h

INT

R/W

22

_22_PLC_set_val2

PLC setpoint 2

100% = 4000h

INT

R/W

23

_23_PLC_set_val3

PLC setpoint 3

100% = 4000h

INT

R/W

24

_24_PLC_set_val4

PLC setpoint 4

100% = 4000h

INT

R/W

25

_25_PLC_set_val5

PLC setpoint 5

100% = 4000h

INT

R/W

26

_26_PLC_additional_control_word1

PLC additional control
word 1

Corresponds to USS profile

INT

R/W

27

_27_PLC_additional_control_word2

PLC additional control
word 2

Corresponds to USS profile

INT

R/W

28

_28_PLC_status_word

PLC status word

Corresponds to USS profile

INT

R/W

29

_29_PLC_act_val1

PLC actual value 1

100% = 4000h

INT

R/W

30

_30_PLC_act_val2

PLC actual value 2

100% = 4000h

INT

R/W

31

_31_PLC_act_val3

PLC actual value 3

100% = 4000h

INT

R/W

32

_32_PLC_act_val4

PLC actual value 4

100% = 4000h

INT

R/W

33

_33_PLC_act_val5

PLC actual value 5

100% = 4000h

INT

R/W