4 "expert" menu, 1 "system" submenu, Ä 70) – Pyromation T82 User Manual
Page 70
Operating menu and parameter description
T82
70
13.4
"Expert" menu
The parameter groups for the Expert setup contain all the parameters of the "Display/operation",
"Setup" and "Diagnostics" operating menus, as well as other parameters that are solely reserved
for experts.
13.4.1 "System" submenu
Damping
Navigation
Expert ® System ® Damping
Description
Use this function to set the time constant for current output damping.
User input
0 to 120 s
Factory settings
0.00 s
Additional information
The current output reacts with an exponential delay to fluctuations in the measured value. The
time constant of this delay is specified by this parameter. If a low time constant is entered, the
current output reacts quickly to the measured value. On the other hand, if a high time constant is
entered, the current output reaction is delayed.
Alarm delay
Navigation
Expert ® System ® Alarm delay
Description
Use this function to set the delay time during which a diagnostics signal is suppressed before it is
output.
User input
0 to 5 s
Factory settings
2 s
Mains filter
Navigation
Expert ® System ® Mains filter
Description
Use this function to select the mains filter for A/D conversion.
Options:
• 50Hz
• 60Hz
Factory setting
50Hz